Gateway startup leaks aiohttp.ClientSession (and other partial-init resources) when an adapter's connect() returns False or raises. The adapter is never added to self.adapters, so the shutdown path at gateway/run.py:2426 never calls disconnect() on it — Python GC later logs 'Unclosed client session' at process exit. Seen on 2026-04-18 18:08:16 during a double --replace takeover cycle: one of the partial-init sessions survived past shutdown and emitted the warning right before status=75/TEMPFAIL. Fix: - New GatewayRunner._safe_adapter_disconnect() helper — calls adapter.disconnect() and swallows any exception. Used on error paths. - Connect loop calls it in both failure branches: success=False and except Exception. - Adapter disconnect() implementations are already expected to be idempotent and tolerate partial-init state (they all guard on self._http_session / self._bridge_process before touching them). Tests: tests/gateway/test_safe_adapter_disconnect.py — 3 cases verify the helper forwards to disconnect, swallows exceptions, and tolerates platform=None. |
||
|---|---|---|
| .. | ||