srojk34 f10851e3fd fix(computer-use): sanitize subprocess env in cua-driver CLI fallback transport
_CuaDriverSession._call_tool_via_cli() (the EAGAIN/silent-empty MCP
fallback transport) invokes `cua-driver call <tool> <json>` via
subprocess.run() with no env= argument, so the third-party cua-driver
binary inherits the full, unsanitized parent environment. The primary
MCP spawn site (_lifecycle_coro) already applies
_sanitize_subprocess_env(cua_driver_child_env()) before opening the
stdio client, per the same policy #53503/#55709 established for other
subprocess spawn points — this fallback path, added alongside the
EAGAIN/silent-empty-capture hardening, missed it.

Fix: apply the same env=_sanitize_subprocess_env(cua_driver_child_env())
to the subprocess.run() call in _call_tool_via_cli(), mirroring the
sanctioned spawn site exactly (telemetry policy applied first, then
Hermes-managed secrets filtered).
2026-07-05 13:57:20 -07:00
..
__init__.py feat(computer-use): cua-driver backend, universal any-model schema 2026-05-08 11:07:38 -07:00
backend.py feat(computer_use): cross-platform cua-driver (macOS/Windows/Linux) 2026-06-22 06:42:30 -07:00
cua_backend.py fix(computer-use): sanitize subprocess env in cua-driver CLI fallback transport 2026-07-05 13:57:20 -07:00
doctor.py feat(computer_use): disable cua-driver telemetry by default, add opt-in (#50842) 2026-06-22 09:57:16 -07:00
permissions.py revert(windows): roll back terminal-popup PRs #53791 #53810 #53829 (#53853) 2026-06-27 15:59:00 -07:00
schema.py feat(computer-use): add whole-screen/desktop capture target 2026-06-22 12:21:58 -07:00
tool.py fix(computer_use): reconcile Linux gate with stale "gated off" comments 2026-06-22 06:42:30 -07:00
vision_routing.py fix(computer_use): honor custom vision routing 2026-06-07 02:09:20 -07:00