mirror of
https://github.com/NousResearch/hermes-agent.git
synced 2026-07-12 13:52:15 +00:00
Builds on the salvaged force-exit fix: - Route the start_gateway() SystemExit paths (clean-fatal-config #51228, planned-restart, service-restart) through the same os._exit backstop. Those paths previously fell through to normal interpreter finalization, leaving them vulnerable to the SAME wedged-non-daemon-thread hang the boolean-return paths now avoid. main() catches SystemExit and converts its code (None->0, int->code, str->1) to os._exit. Every exit path is now wedge-proof. - Document in the helper why bypassing atexit is safe (remove_pid_file + release_gateway_runtime_lock are performed explicitly in start_gateway teardown) and why logging is not flushed (synchronous RotatingFileHandlers). - Tests: assert termination via os._exit not SystemExit (adapted from @AgenticSpark's PR #53122, a duplicate of #53121), plus SystemExit(78) is routed through os._exit(78) and SystemExit(None) maps to os._exit(0).
127 lines
4.7 KiB
Python
127 lines
4.7 KiB
Python
from types import SimpleNamespace
|
|
from unittest.mock import Mock
|
|
|
|
import pytest
|
|
|
|
import gateway.run as gateway_run
|
|
|
|
|
|
class _ExitCalled(Exception):
|
|
def __init__(self, code: int):
|
|
super().__init__(code)
|
|
self.code = code
|
|
|
|
|
|
def _raise_exit(code: int) -> None:
|
|
raise _ExitCalled(code)
|
|
|
|
|
|
def test_main_force_exits_zero_after_clean_shutdown(monkeypatch):
|
|
async def fake_start_gateway(config=None):
|
|
return True
|
|
|
|
stdout = SimpleNamespace(flush=Mock())
|
|
stderr = SimpleNamespace(flush=Mock())
|
|
|
|
monkeypatch.setattr(gateway_run, "start_gateway", fake_start_gateway)
|
|
monkeypatch.setattr(gateway_run.os, "_exit", _raise_exit)
|
|
monkeypatch.setattr(gateway_run.sys, "argv", ["gateway.run"])
|
|
monkeypatch.setattr(gateway_run.sys, "stdout", stdout)
|
|
monkeypatch.setattr(gateway_run.sys, "stderr", stderr)
|
|
|
|
with pytest.raises(_ExitCalled) as exc_info:
|
|
gateway_run.main()
|
|
|
|
assert exc_info.value.code == 0
|
|
stdout.flush.assert_called_once_with()
|
|
stderr.flush.assert_called_once_with()
|
|
|
|
|
|
def test_main_force_exits_one_after_failed_shutdown(monkeypatch):
|
|
async def fake_start_gateway(config=None):
|
|
return False
|
|
|
|
stdout = SimpleNamespace(flush=Mock())
|
|
stderr = SimpleNamespace(flush=Mock())
|
|
|
|
monkeypatch.setattr(gateway_run, "start_gateway", fake_start_gateway)
|
|
monkeypatch.setattr(gateway_run.os, "_exit", _raise_exit)
|
|
monkeypatch.setattr(gateway_run.sys, "argv", ["gateway.run"])
|
|
monkeypatch.setattr(gateway_run.sys, "stdout", stdout)
|
|
monkeypatch.setattr(gateway_run.sys, "stderr", stderr)
|
|
|
|
with pytest.raises(_ExitCalled) as exc_info:
|
|
gateway_run.main()
|
|
|
|
assert exc_info.value.code == 1
|
|
stdout.flush.assert_called_once_with()
|
|
stderr.flush.assert_called_once_with()
|
|
|
|
|
|
def test_main_terminates_via_os_exit_not_systemexit(monkeypatch):
|
|
"""The terminating call must be os._exit, NOT sys.exit — SystemExit is
|
|
exactly what triggers the Py_FinalizeEx non-daemon-thread join hang this
|
|
fixes (#53107). If main() ever regresses to sys.exit(), SystemExit would
|
|
propagate instead of our os._exit sentinel and this test would fail.
|
|
|
|
Test contributed by @AgenticSpark (PR #53122, duplicate of #53121)."""
|
|
async def fake_start_gateway(config=None):
|
|
return False
|
|
|
|
stdout = SimpleNamespace(flush=Mock())
|
|
stderr = SimpleNamespace(flush=Mock())
|
|
|
|
monkeypatch.setattr(gateway_run, "start_gateway", fake_start_gateway)
|
|
monkeypatch.setattr(gateway_run.os, "_exit", _raise_exit)
|
|
monkeypatch.setattr(gateway_run.sys, "argv", ["gateway.run"])
|
|
monkeypatch.setattr(gateway_run.sys, "stdout", stdout)
|
|
monkeypatch.setattr(gateway_run.sys, "stderr", stderr)
|
|
|
|
# Our os._exit sentinel must be what terminates main() — not SystemExit.
|
|
with pytest.raises(_ExitCalled):
|
|
gateway_run.main()
|
|
|
|
|
|
def test_main_routes_systemexit_through_os_exit(monkeypatch):
|
|
"""start_gateway raises SystemExit on the clean-fatal-config (#51228),
|
|
planned-restart, and service-restart paths. main() must catch it and route
|
|
the carried code through os._exit too, so those paths are equally wedge-proof
|
|
(#53107) — a SystemExit propagating to interpreter finalization would join a
|
|
stuck non-daemon worker and hang. Verifies the explicit code (e.g. 78) is
|
|
preserved through the os._exit backstop."""
|
|
async def fake_start_gateway(config=None):
|
|
raise SystemExit(78)
|
|
|
|
stdout = SimpleNamespace(flush=Mock())
|
|
stderr = SimpleNamespace(flush=Mock())
|
|
|
|
monkeypatch.setattr(gateway_run, "start_gateway", fake_start_gateway)
|
|
monkeypatch.setattr(gateway_run.os, "_exit", _raise_exit)
|
|
monkeypatch.setattr(gateway_run.sys, "argv", ["gateway.run"])
|
|
monkeypatch.setattr(gateway_run.sys, "stdout", stdout)
|
|
monkeypatch.setattr(gateway_run.sys, "stderr", stderr)
|
|
|
|
with pytest.raises(_ExitCalled) as exc_info:
|
|
gateway_run.main()
|
|
|
|
# The SystemExit(78) must be converted to os._exit(78), not propagated.
|
|
assert exc_info.value.code == 78
|
|
stdout.flush.assert_called_once_with()
|
|
stderr.flush.assert_called_once_with()
|
|
|
|
|
|
def test_main_systemexit_none_code_maps_to_zero(monkeypatch):
|
|
"""SystemExit() with no code (or None) is a clean exit → os._exit(0)."""
|
|
async def fake_start_gateway(config=None):
|
|
raise SystemExit()
|
|
|
|
monkeypatch.setattr(gateway_run, "start_gateway", fake_start_gateway)
|
|
monkeypatch.setattr(gateway_run.os, "_exit", _raise_exit)
|
|
monkeypatch.setattr(gateway_run.sys, "argv", ["gateway.run"])
|
|
monkeypatch.setattr(gateway_run.sys, "stdout", SimpleNamespace(flush=Mock()))
|
|
monkeypatch.setattr(gateway_run.sys, "stderr", SimpleNamespace(flush=Mock()))
|
|
|
|
with pytest.raises(_ExitCalled) as exc_info:
|
|
gateway_run.main()
|
|
|
|
assert exc_info.value.code == 0
|