hermes-agent/tests/gateway/test_safe_adapter_disconnect.py
StellarisW f57157a128 fix(gateway): recover Discord websocket and event-loop stalls
Replace REST-based Discord liveness probe with local WebSocket/heartbeat
state detection. REST success doesn't prove Gateway event delivery — a
half-closed WebSocket can leave Bot.start() alive while REST returns 200.
Now samples ready/open/ACK state and heartbeat latency; consecutive
unhealthy samples emit one retryable fatal code so GatewayRunner rebuilds
the adapter through the existing reconnect path.

Also fixes three lifecycle gaps in the recovery path:
1. asyncio.wait_for() can remain blocked if adapter cleanup swallows
   cancellation — now uses bounded asyncio.wait() with task detachment.
2. Multiplexed secondary-profile adapters had no profile-scoped reconnect
   owner — now uses one runner-owned reconnect slot per profile.
3. An in-flight turn could send its final text through the disconnected
   adapter after a replacement was registered — now resolves the live
   same-profile replacement for unsent final responses only (message IDs
   never migrate, edits/deletes stay on the old transport).

Adds an opt-in Linux/systemd event-loop watchdog (gateway.systemd_watchdog_seconds,
default 0) for the failure mode where the whole asyncio loop stops making
progress and no in-process liveness task can run. stdlib-only sd_notify,
Type=notify/WatchdogSec generation, READY/STOPPING lifecycle.

Co-authored-by: 王鑫 <wx.xw@bytedance.com>
2026-07-18 20:01:55 +05:30

123 lines
4.3 KiB
Python

"""Regression tests: failed-connect path must call adapter.disconnect().
When adapter.connect() returns False or raises, the adapter may have
allocated resources (aiohttp.ClientSession, poll tasks, child
subprocesses) before giving up. Without a defensive disconnect() call
these leak and surface as "Unclosed client session" warnings at
process exit (seen on the 2026-04-18 18:08:16 gateway restart).
The fix: gateway/run.py wraps each adapter connect() with a safety-net
call to _safe_adapter_disconnect() in the failure branches.
"""
import asyncio
import logging
from unittest.mock import AsyncMock, MagicMock
import pytest
from gateway.config import Platform
from gateway.run import GatewayRunner
@pytest.fixture
def bare_runner():
"""A GatewayRunner shell that only needs to support _safe_adapter_disconnect."""
return object.__new__(GatewayRunner)
@pytest.mark.asyncio
async def test_safe_disconnect_calls_adapter_disconnect(bare_runner):
"""The helper forwards to adapter.disconnect()."""
adapter = MagicMock()
adapter.disconnect = AsyncMock(return_value=None)
await bare_runner._safe_adapter_disconnect(adapter, Platform.TELEGRAM)
adapter.disconnect.assert_awaited_once()
@pytest.mark.asyncio
async def test_safe_disconnect_swallows_exceptions(bare_runner):
"""An exception in adapter.disconnect() must not propagate — the
caller is already on an error path."""
adapter = MagicMock()
adapter.disconnect = AsyncMock(side_effect=RuntimeError("partial init"))
# Must NOT raise
await bare_runner._safe_adapter_disconnect(adapter, Platform.TELEGRAM)
adapter.disconnect.assert_awaited_once()
@pytest.mark.asyncio
async def test_safe_disconnect_handles_none_platform(bare_runner):
"""Logging path must tolerate platform=None."""
adapter = MagicMock()
adapter.disconnect = AsyncMock(side_effect=ValueError("nope"))
await bare_runner._safe_adapter_disconnect(adapter, None)
adapter.disconnect.assert_awaited_once()
@pytest.mark.asyncio
async def test_safe_disconnect_times_out_and_continues(bare_runner, monkeypatch, caplog):
"""A wedged adapter disconnect must not block gateway shutdown."""
monkeypatch.setenv("HERMES_GATEWAY_ADAPTER_DISCONNECT_TIMEOUT", "0.001")
adapter = MagicMock()
async def hang():
await asyncio.sleep(60)
adapter.disconnect = AsyncMock(side_effect=hang)
with caplog.at_level(logging.WARNING, logger="gateway.run"):
await bare_runner._safe_adapter_disconnect(adapter, Platform.FEISHU)
adapter.disconnect.assert_awaited_once()
assert "Timed out after 0.0s while disconnecting feishu adapter" in caplog.text
@pytest.mark.asyncio
async def test_safe_disconnect_detaches_cancellation_swallowing_disconnect(
bare_runner, monkeypatch, caplog
):
"""A disconnect that catches cancellation cannot block fatal recovery.
``asyncio.wait_for`` cancels its child at the deadline but then waits for
it to finish. A half-closed transport can catch that cancellation while
unwinding, so the runner must detach the old close task and continue to the
reconnect queue instead of waiting indefinitely.
"""
monkeypatch.setenv("HERMES_GATEWAY_ADAPTER_DISCONNECT_TIMEOUT", "0.01")
adapter = MagicMock()
started = asyncio.Event()
release = asyncio.Event()
finished = asyncio.Event()
async def swallow_cancellation():
started.set()
while not release.is_set():
try:
await release.wait()
except asyncio.CancelledError:
continue
finished.set()
adapter.disconnect = AsyncMock(side_effect=swallow_cancellation)
operation = asyncio.create_task(
bare_runner._safe_adapter_disconnect(adapter, Platform.FEISHU)
)
await started.wait()
done, _pending = await asyncio.wait({operation}, timeout=0.2)
try:
assert operation in done
assert "Timed out after 0.0s while disconnecting feishu adapter" in caplog.text
finally:
# The implementation must detach rather than abandon the old task.
# Release it here so this test leaves no cancellation-swallowing task
# behind when it runs against the pre-fix implementation.
release.set()
await asyncio.wait({operation}, timeout=0.2)
await asyncio.wait_for(finished.wait(), timeout=0.2)