Commit graph

10 commits

Author SHA1 Message Date
Teknium
d3d621f7c3
revert(windows): roll back terminal-popup PRs #53791 #53810 #53829 (#53853)
* Revert "fix(windows): capture is not a no-window boundary; route flashing spawns through chokepoint (#53829)"

This reverts commit 2ecca1e7d3.

* Revert "fix(windows): stop terminal-window popups from background spawns (#53810)"

This reverts commit 5db1430af9.

* Revert "fix(windows): stop subprocess console-window popups + add CI guard (#53791)"

This reverts commit ef17cd204d.
2026-06-27 15:59:00 -07:00
brooklyn!
5db1430af9
fix(windows): stop terminal-window popups from background spawns (#53810)
* fix(windows): stop terminal-window popups from background spawns

Native-Windows desktop/gateway users saw cmd/conhost windows flash on
gateway restart, image paste, the dashboard Projects tree, voice notes,
and ~5 min after closing the app (detached cron). Two root causes:

- Console-subsystem exes (taskkill, schtasks, wmic, netstat, tasklist,
  agent-browser, git, ffmpeg, powershell, git-bash) spawned via raw
  subprocess allocate a fresh console when the launching process has
  none (pythonw desktop backend / detached gateway) - even with output
  captured.
- uv venv pythonw shims re-exec console python.exe, so Python children
  get a console regardless of how they're launched.

Fixes:
- Single hidden-spawn primitive (_subprocess_compat.run/.popen) that ORs
  CREATE_NO_WINDOW on Windows, no-op on POSIX. Route every Hermes-owned
  console-exe spawn through it.
- FreeConsole() catch-all in hermes_bootstrap: any Python child that
  exclusively owns an auto-allocated console detaches it at startup
  (GetConsoleProcessList()==1 gate leaves shared interactive consoles
  untouched).
- Replace PowerShell/wmic gateway PID scans with in-process psutil.
- Skip schtasks queries on non-interactive desktop restarts.
- Prefer native agent-browser .exe over .cmd shims.
- Guard test bans raw subprocess spawns of the Windows-only console
  tools repo-wide so the popup class can't regress.

* fix(windows): scope FreeConsole to background entry points; fix merge fallout

Console detach review (per #53810 feedback): GetConsoleProcessList()==1 can't
tell a uv pythonw->python phantom console apart from a user opening the
interactive CLI/TUI in its own fresh console (double-click, shortcut, ConPTY) —
both report a single attached process with a tty. Running FreeConsole() in the
import-time bootstrap therefore risked detaching a legitimately-interactive
terminal.

- Extract FreeConsole into explicit hermes_bootstrap.detach_orphan_console();
  remove it from apply_windows_utf8_bootstrap() (import side effect).
- Call it only from known background mains: gateway run, dashboard backend
  (start_server, what the desktop spawns), cron standalone, tui_gateway entry,
  slash worker. Interactive CLI/TUI never calls it.
- Behavior-contract tests: frees only when solo owner, leaves shared console,
  no-op without console / on POSIX, and asserts it's not an import side effect.

Merge fallout from origin/main (#53791):
- local.py: 3-way merge left a dangling **_popen_kwargs (NameError crashing
  every terminal init). _subprocess_compat.popen already hides the window, so
  drop it.
- discord adapter: merge stacked an undefined windows_hide_flags() onto the
  primitive call; drop the redundant arg.
- test_gateway: scan now goes psutil-first (zero spawn); rewrite the
  case-variant test to drive that production path.

* test(claw): mock _subprocess_compat.run seam for Windows process scan

claw.py's Windows tasklist/powershell scan routes through the hidden-spawn
primitive; the tests still patched claw_mod.subprocess, so on win32 the mock
was never hit and real spawns returned nothing. Patch the actual seam.
2026-06-27 14:02:24 -07:00
Gille
bf0513bca0 test(windows): align gateway restart CI coverage 2026-06-25 14:42:38 -07:00
lEWFkRAD
433db17c0a
fix(windows): harden gateway scheduled task (#45610)
* fix(windows): harden gateway scheduled task

* fix(windows): launch gateway scheduled task via console-less wscript

The Scheduled Task ran the gateway through cmd.exe, which allocates a
console. During logon Windows broadcasts CTRL_CLOSE_EVENT to console
process groups, reaping cmd.exe and the half-initialized gateway with
STATUS_CONTROL_C_EXIT (0xC000013A) - which Task Scheduler treats as a
user cancel, so RestartOnFailure never fires and the gateway vanishes on
every reboot (issue #45599 root cause #1).

Add a console-less .vbs launcher (wscript.exe -> pythonw.exe, both
GUI-subsystem) mirroring the gateway.cmd env + argv, and point the task
action at it. The .cmd stays for the Startup-folder fallback and /Run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>

---------

Co-authored-by: Jeff <jeffrobodie@gmail.com>
Co-authored-by: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 16:07:52 -07:00
Dusk1e
2059707fce fix(gateway-windows): anchor detached/startup cwd at HERMES_HOME 2026-06-03 19:37:29 -07:00
xxxigm
df848bd2da test(gateway): cover schtasks locale-safe decoding on Windows
Assert _exec_schtasks passes an explicit encoding and errors="replace" to
subprocess.run, and that _schtasks_encoding falls back to utf-8 when the
locale lookup is empty or raises (#38172).
2026-06-03 09:29:19 -07:00
Teknium
10ee4a729b
fix(gateway): drain on Windows hermes gateway stop so sessions survive restart (#33798)
Sessions now survive `hermes gateway stop` / `restart` on native Windows.
Previously the gateway died on schtasks `/End` + os.kill SIGTERM without
ever running the drain loop, so the v0.13.0 session-resume feature (#21192)
silently broke on Windows: `resume_pending=True` was never written, and
the next boot started with a blank conversation history (issue #33778).

Root cause is twofold and the reporter only identified half of it:

1. `hermes_cli/gateway_windows.py::stop()` did not write the
   `planned_stop_marker` before signalling. The reporter caught this.

2. The bigger reason: `asyncio.add_signal_handler` raises
   NotImplementedError for SIGTERM/SIGINT on Windows, so even if the
   marker had been written, the gateway's existing SIGTERM handler
   (which is what calls `runner.stop()` and the `mark_resume_pending`
   loop) was never invoked. Writing the marker would have been
   necessary-but-insufficient.

The fix has two parts:

* gateway/run.py: new `_run_planned_stop_watcher` daemon thread polls
  for the planned-stop marker file every 0.5s. When the marker appears
  it `loop.call_soon_threadsafe(shutdown_signal_handler, None)` — the
  same shutdown path a real SIGTERM would have driven, including the
  pre-drain `mark_resume_pending` writes (run.py:5977) and graceful
  drain wait. The existing signal handler already accepts
  `received_signal=None` and falls through to
  `consume_planned_stop_marker_for_self()`, so no handler changes
  needed. Runs on every platform as cheap belt-and-suspenders.

* hermes_cli/gateway_windows.py: `stop()` now writes the marker for
  the running gateway PID and waits up to `agent.restart_drain_timeout`
  (default 30s) for the PID to exit cleanly. On clean drain, the kill
  sweep is non-forceful; on timeout, escalates to
  `kill_gateway_processes(force=True)` which routes to taskkill /T /F
  per `references/windows-native-support.md`.

Validation:

* 7 new tests in tests/gateway/test_planned_stop_watcher.py covering:
  marker→handler dispatch, no-marker idle, already-draining skip,
  not-yet-running skip, stop_event responsiveness, fire-once
  semantics, error tolerance.
* 8 new tests in tests/hermes_cli/test_gateway_windows.py covering:
  marker-before-kill ordering, clean-drain skips force-kill,
  drain-timeout escalates to force=True, no-pid-skips-drain,
  invalid-pid handling, fast-exit success, timeout failure,
  marker-write-failure tolerance.
* E2E (Linux, detached orphan): write_planned_stop_marker(pid) +
  `_drain_gateway_pid(pid, 5.0)` returns True in 0.5s after the
  victim sees the marker and exits. Tested with a double-forked
  subprocess so the test parent isn't holding it as a zombie.
* Targeted: tests/gateway/{restart_drain,restart_resume_pending,
  signal,signal_format,status,shutdown_forensics,approve_deny_commands,
  planned_stop_watcher} + tests/hermes_cli/{gateway_windows,
  gateway_service} → 519/519.

What was wrong with the reporter's claim (for future archaeology): they
described the symptom as "no `resume_pending=True` written to
`sessions.json`" — but Hermes uses `state.db` (SQLite), not
`sessions.json`, and `mark_resume_pending` is called regardless of
the marker (the marker only affects exit code 0 vs 1 for systemd
revival semantics). The real session-loss path is the missing drain
on Windows, not a missing marker. Both halves are fixed here.

Closes #33778.
2026-05-28 03:25:32 -07:00
teknium1
a19eb54727 test(gateway-windows): make ctypes.windll monkeypatch tolerant on non-Windows
Linux/macOS CI runners don't have ctypes.windll, so the elevated-gateway
test fails at module load. Adding raising=False lets monkeypatch install
the mock attribute without first requiring it to exist.
2026-05-19 11:23:15 -07:00
nekwo
d948de39e9 fix(gateway): harden Windows gateway install lifecycle
Preserve Windows profile install decisions across UAC handoff, avoid visible console windows by launching via pythonw, make repeated install/start idempotent, recreate stale Scheduled Tasks, and separate start-now from login auto-start behavior. Add Windows gateway regression coverage and systemd setup tests for the shared install flow.
2026-05-19 11:23:15 -07:00
Martin
417a653d9e fix(gateway): prevent Windows Telegram /restart leaving gateway stopped 2026-05-18 22:38:08 -07:00