After a prolonged outage the in-process network-error ladder escalates to
fatal and GatewayRunner._platform_reconnect_watcher rebuilds a fresh adapter
that reconnects through the bootstrap path. That path called
start_polling(drop_pending_updates=True), discarding every update Telegram
queued during the outage — all messages sent while the bot was down were
silently lost. The in-process ladder and 409-conflict handler already passed
drop_pending_updates=False; only bootstrap did not distinguish a cold first
boot from a reconnect.
Thread an is_reconnect signal from the watcher through
_connect_adapter_with_timeout into adapter.connect(). The base
BasePlatformAdapter.connect() gains a keyword-only is_reconnect=False so every
adapter inherits a tolerant signature (no per-platform breakage when the
runner forwards the kwarg). Telegram translates is_reconnect into
drop_pending_updates=not is_reconnect on both the polling and webhook bootstrap
calls. Cold boot still drops the stale queue; a watcher reconnect preserves it.
Fixes#46621.
Co-authored-by: annguyenNous <annguyen@nousresearch.com>
Co-authored-by: kyssta-exe <kyssta-exe@users.noreply.github.com>
Co-authored-by: Kewe63 <Kewe63@users.noreply.github.com>
* fix(gateway): auto-start after container restart via planned-stop marker
On Docker (s6-overlay), the gateway runs as a dynamically-registered s6
service. When the container stops/restarts/upgrades, s6 sends the gateway
a plain SIGTERM. The shutdown path (_stop_impl) ended with an
unconditional _update_runtime_status("stopped"), persisting
gateway_state=stopped to the volume. container_boot.py reads that on the
next boot and only auto-starts gateways whose last state was "running"
(_AUTOSTART_STATES) — so after a routine `docker compose up
--force-recreate` the gateway stays down and messaging channels silently
go dark, with no error surfaced (issue #42675).
The codebase already distinguishes intentional stops from unexpected
signals via the planned-stop marker (write_planned_stop_marker /
consume_planned_stop_marker_for_self): `hermes gateway stop`,
systemd/launchd ExecStop, and Ctrl+C write a marker before signalling,
so the handler classifies them as planned. An unmarked SIGTERM
(container/s6 restart, OOM, bare kill) is signal-initiated.
This wires that existing classification through to the state persist,
rather than adding unreliable signal-source inference:
- run.py: GatewayRunner._signal_initiated_shutdown, set in
shutdown_signal_handler's unmarked-signal branch. In _stop_impl, a
signal-initiated (non-restart) teardown now persists "running" instead
of "stopped" — preserving the operator's run-intent and overwriting the
mid-shutdown "draining" marker so _AUTOSTART_STATES matches on reboot.
Operator stops and restarts persist "stopped" as before.
- service_manager.py: S6ServiceManager.stop() now writes the planned-stop
marker for the supervised PID (read from s6-svstat) before `s6-svc -d`,
so an in-container `hermes gateway stop` is correctly classified as
intentional (parity with the systemd/launchd/host stop paths, which
already mark). Best-effort: a marker-write failure falls back to the
safe signal-initiated path.
Tests: shutdown persist-decision table (signal→running, operator→stopped,
restart→stopped), s6 stop marker write + svstat PID parse + failure
tolerance. The signal→running and s6-marker tests fail without the
respective source change. Verified end-to-end against a container built
from this branch: an unmarked SIGTERM to the live gateway leaves
gateway_state=running (shutdown-context log confirms signal path);
existing real container-restart suite still green.
* docs(docker): clarify gateway autostart distinguishes operator-stop from container-kill
The per-profile-supervision section described the autostart-across-restart
contract as "running gateways come back, stopped stay stopped" without
spelling out what records 'stopped'. That contract was the source of
#42675 confusion: users expected a restart to bring the gateway back and
it didn't. With the write-side fix, only an explicit `hermes gateway stop`
records 'stopped'; container/s6 restart SIGTERMs (incl. image upgrades and
unexpected exits) leave the state 'running' so the gateway auto-starts.
Make that distinction explicit in both the multi-profile and
per-profile-supervision sections.
* test(docker): real-restart autostart E2E for #42675
Adds test_live_gateway_autostarts_after_real_restart_without_manual_state_stamp:
a live s6-supervised gateway is killed by an actual `docker restart`
SIGTERM (no manual gateway_state stamp, no planned-stop marker) and must
auto-start on the next boot. Exercises the WRITE side of the fix that the
existing stamp-based tests bypass.
Verified to FAIL against an origin/main image (reconciler logs
prior_state=stopped action=registered — the #42675 bug) and PASS against
the fixed image (prior_state=running action=started).
Remove unused imports (F401) and duplicate/shadowed import
redefinitions (F811) across the codebase using ruff's safe
autofixes. No behavioral changes -- imports only.
- ~1400 safe autofixes applied across 644 files (net -1072 lines)
- __init__.py re-exports preserved (excluded from F401 removal so
public re-export surfaces stay intact)
- Re-exports that are imported or monkeypatched by tests but look
unused in their defining module are kept with explicit # noqa:
F401 (gateway/run.py load_dotenv; run_agent re-exports from
agent.message_sanitization, agent.context_compressor,
agent.retry_utils, agent.prompt_builder, agent.process_bootstrap,
agent.codex_responses_adapter)
- Unsafe F841 (unused-variable) fixes deliberately skipped -- those
can change behavior when the RHS has side effects
- ruff lints remain disabled in pyproject.toml (only PLW1514 is
selected); this is a one-time cleanup, not a config change
Verification:
- python -m compileall: clean
- pytest --collect-only: all 27161 tests collect (zero import errors)
- core entry points import clean (run_agent, model_tools, cli,
toolsets, hermes_state, batch_runner, gateway)
- static scan: every name any test imports directly from an edited
module still resolves
Follow-up on top of Zyproth's session-source cache: swap the unbounded
dict for an OrderedDict with a 512-entry LRU cap so long-running
gateways can't accumulate stale entries for dead sessions forever.
- self._session_sources is now an OrderedDict
- _cache_session_source() move_to_end + popitem(last=False) above cap
- _get_cached_session_source() move_to_end on hit (LRU read bump)
- restart_test_helpers.py wires OrderedDict + _session_sources_max
Prefer session_store origin over _parse_session_key() for shutdown
notifications. Fixes misrouting when chat identifiers contain colons
(e.g. Matrix room IDs like !room123:example.org).
Falls back to session-key parsing when no persisted origin exists.
Co-authored-by: Ruzzgar <ruzzgarcn@gmail.com>
Ref: #12766
Three fixes for gateway lifecycle stability:
1. Notify active sessions before shutdown (#new)
When the gateway receives SIGTERM or /restart, it now sends a
notification to every chat with an active agent BEFORE starting
the drain. Users see:
- Shutdown: 'Gateway shutting down — your task will be interrupted.'
- Restart: 'Gateway restarting — use /retry after restart to continue.'
Deduplicates per-chat so group sessions with multiple users get
one notification. Best-effort: send failures are logged and swallowed.
2. Skip .clean_shutdown marker when drain timed out
Previously, a graceful SIGTERM always wrote .clean_shutdown, even if
agents were force-interrupted when the drain timed out. This meant
the next startup skipped session suspension, leaving interrupted
sessions in a broken state (trailing tool response, no final message).
Now the marker is only written if the drain completed without timeout,
so interrupted sessions get properly suspended on next startup.
3. Post-restart health check for hermes update (#6631)
cmd_update() now verifies the gateway actually survived after
systemctl restart (sleep 3s + is-active check). If the service
crashed immediately, it retries once. If still dead, prints
actionable diagnostics (journalctl command, manual restart hint).
Also closes#8104 — already fixed on main (the /restart handler
correctly detects systemd via INVOCATION_ID and uses via_service=True).
Test plan:
- 6 new tests for shutdown notifications (dedup, restart vs shutdown
messaging, sentinel filtering, send failure resilience)
- Existing restart drain + update tests pass (47 total)