Remove unused imports (F401) and duplicate/shadowed import
redefinitions (F811) across the codebase using ruff's safe
autofixes. No behavioral changes -- imports only.
- ~1400 safe autofixes applied across 644 files (net -1072 lines)
- __init__.py re-exports preserved (excluded from F401 removal so
public re-export surfaces stay intact)
- Re-exports that are imported or monkeypatched by tests but look
unused in their defining module are kept with explicit # noqa:
F401 (gateway/run.py load_dotenv; run_agent re-exports from
agent.message_sanitization, agent.context_compressor,
agent.retry_utils, agent.prompt_builder, agent.process_bootstrap,
agent.codex_responses_adapter)
- Unsafe F841 (unused-variable) fixes deliberately skipped -- those
can change behavior when the RHS has side effects
- ruff lints remain disabled in pyproject.toml (only PLW1514 is
selected); this is a one-time cleanup, not a config change
Verification:
- python -m compileall: clean
- pytest --collect-only: all 27161 tests collect (zero import errors)
- core entry points import clean (run_agent, model_tools, cli,
toolsets, hermes_state, batch_runner, gateway)
- static scan: every name any test imports directly from an edited
module still resolves
Four recent security PRs landed on main with stale/missing test updates,
breaking 4 test shards on every subsequent PR's CI run:
- test_discord_bot_auth_bypass.py (PR #30742c3caca658):
DISCORD_ALLOWED_ROLES no longer bypasses _is_user_authorized.
Inverted 3 tests to assert the new (correct) behavior: role config
alone does NOT authorize at the gateway layer.
- test_msgraph_webhook.py (PR #301694ca77f105):
adapter.is_connected is a @property, not a method. Test was calling
it with () after the connect() change; TypeError: 'bool' is not
callable. Removed the parens.
- test_feishu_approval_buttons.py (PR #30744bdb97b857):
Card-action callbacks now go through _allow_group_message
authorization. 3 tests in TestCardActionCallbackResponse didn't
populate adapter._allowed_group_users so the operator's open_id got
rejected. Added the allowlist setup to each test, matching the
existing pattern in test_returns_card_for_approve_action.
Also raise tolerance on test_wait_for_process_kills_subprocess_on_keyboardinterrupt:
the SIGTERM → 3s TimeoutStopSec → SIGKILL → reap chain can exceed 10s
under loaded xdist (40 workers). Bumped _wait_for_pgid_exit timeout
10→30s and worker join timeout 5→15s. Passes 100% in isolation
already; this just makes it tolerant of CI-host load.
Validation: 270/270 tests pass across the 5 affected files.
* fix(interrupt): propagate to concurrent-tool workers + opt-in debug trace
interrupt() previously only flagged the agent's _execution_thread_id.
Tools running inside _execute_tool_calls_concurrent execute on
ThreadPoolExecutor worker threads whose tids are distinct from the
agent's, so is_interrupted() inside those tools returned False no matter
how many times the gateway called .interrupt() — hung ssh / curl / long
make-builds ran to their own timeout.
Changes:
- run_agent.py: track concurrent-tool worker tids in a per-agent set,
fan interrupt()/clear_interrupt() out to them, and handle the
register-after-interrupt race at _run_tool entry. getattr fallback
for the tracker so test stubs built via object.__new__ keep working.
- tools/environments/base.py: opt-in _wait_for_process trace (ENTER,
per-30s HEARTBEAT with interrupt+activity-cb state, INTERRUPT
DETECTED, TIMEOUT, EXIT) behind HERMES_DEBUG_INTERRUPT=1.
- tools/interrupt.py: opt-in set_interrupt() trace (caller tid, target
tid, set snapshot) behind the same env flag.
- tests: new regression test runs a polling tool on a concurrent worker
and asserts is_interrupted() flips to True within ~1s of interrupt().
Second new test guards clear_interrupt() clearing tracked worker bits.
Validation: tests/run_agent/ all 762 pass; tests/tools/ interrupt+env
subset 216 pass.
* fix(interrupt-debug): bypass quiet_mode logger filter so trace reaches agent.log
AIAgent.__init__ sets logging.getLogger('tools').setLevel(ERROR) when
quiet_mode=True (the CLI default). This would silently swallow every
INFO-level trace line from the HERMES_DEBUG_INTERRUPT=1 instrumentation
added in the parent commit — confirmed by running hermes chat -q with
the flag and finding zero trace lines in agent.log even though
_wait_for_process was clearly executing (subprocess pid existed).
Fix: when HERMES_DEBUG_INTERRUPT=1, each traced module explicitly sets
its own logger level to INFO at import time, overriding the 'tools'
parent-level filter. Scoped to the opt-in case only, so production
(quiet_mode default) logs stay quiet as designed.
Validation: hermes chat -q with HERMES_DEBUG_INTERRUPT=1 now writes
'_wait_for_process ENTER/EXIT' lines to agent.log as expected.
* fix(cli): SIGTERM/SIGHUP no longer orphans tool subprocesses
Tool subprocesses spawned by the local environment backend use
os.setsid so they run in their own process group. Before this fix,
SIGTERM/SIGHUP to the hermes CLI killed the main thread via
KeyboardInterrupt but the worker thread running _wait_for_process
never got a chance to call _kill_process — Python exited, the child
was reparented to init (PPID=1), and the subprocess ran to its
natural end (confirmed live: sleep 300 survived 4+ min after SIGTERM
to the agent until manual cleanup).
Changes:
- cli.py _signal_handler (interactive) + _signal_handler_q (-q mode):
route SIGTERM/SIGHUP through agent.interrupt() so the worker's poll
loop sees the per-thread interrupt flag and calls _kill_process
(os.killpg) on the subprocess group. HERMES_SIGTERM_GRACE (default
1.5s) gives the worker time to complete its SIGTERM+SIGKILL
escalation before KeyboardInterrupt unwinds main.
- tools/environments/base.py _wait_for_process: wrap the poll loop in
try/except (KeyboardInterrupt, SystemExit) so the cleanup fires
even on paths the signal handlers don't cover (direct sys.exit,
unhandled KI from nested code, etc.). Emits EXCEPTION_EXIT trace
line when HERMES_DEBUG_INTERRUPT=1.
- New regression test: injects KeyboardInterrupt into a running
_wait_for_process via PyThreadState_SetAsyncExc, verifies the
subprocess process group is dead within 3s of the exception and
that KeyboardInterrupt re-raises cleanly afterward.
Validation:
| Before | After |
|---------------------------------------------------------|--------------------|
| sleep 300 survives 4+ min as PPID=1 orphan after SIGTERM | dies within 2 s |
| No INTERRUPT DETECTED in trace | INTERRUPT DETECTED fires + killing process group |
| tests/tools/test_local_interrupt_cleanup | 1/1 pass |
| tests/run_agent/test_concurrent_interrupt | 4/4 pass |