* fix(cron): add default retention to per-run job output to bound disk usage (#52383)
Per-run cron output (cron/output/<job>/<timestamp>.md) is written once
per execution and was never pruned, so a frequently-scheduled job on
a long-running deploy accumulates one file per run indefinitely and
can fill the volume ('no space left on device').
save_job_output() now keeps the most recent N output files per job and
removes older ones. N defaults to 50 and is configurable via
cron.output_retention; a non-positive value disables pruning for
operators who manage cleanup externally.
Salvaged from #52402 by @0xDevNinja.
Closes#52383
* fix(config): add cron.output_retention to DEFAULT_CONFIG
Follow-up to #52383: the retention config key was functional via
get()-with-default but missing from DEFAULT_CONFIG, so the deep-merge
wouldn't auto-populate it for new installs. Add it explicitly.
---------
Co-authored-by: 0xDevNinja <manmit0x@gmail.com>
A naive ISO timestamp (e.g. 2026-06-22T20:07:00) was anchored to the
server's local timezone via dt.astimezone(), but the due-check
(get_due_jobs -> _hermes_now()) runs in the CONFIGURED Hermes timezone.
When the two diverge (cloud host on UTC with a different timezone: set,
or vice-versa) the stored instant lands hours off the user's wall-clock
intent, so one-shots never become due and recurring jobs fire at the
wrong time. The ticker stays healthy (heartbeat + success markers fresh)
because every tick finds nothing due, matching the silent no-fire in #51021.
Anchor naive timestamps to _hermes_now().tzinfo so '20:07' means 20:07 on
the same clock the scheduler checks against. The legacy _ensure_aware path
still treats already-stored naive values as server-local for back-compat.
Fixes#51021
When a recurring job's execution time exceeds `interval + grace`, the
scheduler entered a perpetual "missed → fast-forward → skip" loop and the
job effectively never ran again. A real job (`hermes-upstream-contribution`)
logged 42 consecutive "missed" events over 9 hours without executing once.
Timeline (5-min interval, 150s grace, ~15-min execution):
14:00 due → advance next_run_at→14:05 → run (blocks 15 min)
14:15 finishes
14:16 tick: next_run_at=14:05, elapsed 660s > grace 150s → "missed!"
→ fast-forward to 14:21 → continue (SKIP) → does NOT run
... repeats forever for any job whose runtime > interval+grace.
The `continue` (skip execution) in `_get_due_jobs_locked` was designed to
prevent burst-catchup after *gateway downtime* — don't run 6 missed
instances of a 30-min job on restart. But it wrongly applied to a job that
missed its slot because it was *still running*, not because the gateway was
down.
Fix: keep the fast-forward (so accumulated missed slots are still collapsed
to a single next slot — no burst) but fall through to `due.append(job)` so
the job runs ONCE now. The log message is updated to be honest about the new
behavior ("Running now; next run fast-forwarded to: ...").
Behavior note: a recurring job missed during gateway downtime now also fires
once immediately on restart (rather than waiting for its next natural slot).
This is the intended trade-off — the same "run once, don't burst" rule now
applies uniformly to both downtime-misses and long-execution-misses.
Salvaged from #33318 by @liuhao1024 (authorship preserved). Also addresses
the diagnosis in #33361 (@agent-trivi), which proposed the same one-line fix.
Tests: updates `test_stale_past_due_skipped` →
`test_stale_past_due_runs_once_and_fast_forwards` (the old test encoded the
skip behavior); adds `test_long_execution_does_not_perpetually_defer` as a
direct regression for the production loop; updates the F2e timezone test that
relied on the old skip path. Full tests/cron/ suite: 510 passed.
Fixes#33315
Co-authored-by: liuhao1024 <sunsky.lau@gmail.com>
A recurring cron job persists `next_run_at` as an absolute timestamp with a
UTC offset (e.g. `2026-05-19T21:00:00+10:00`). Cron expressions, however,
describe *local wall-clock* intent ("run at 21:00"). When Hermes/system
timezone changes after the timestamp was persisted, the stored instant is
re-interpreted in the new zone: `21:00+10:00` is the instant `13:00+02:00`,
which is `<= now` (13:02+02:00) — so the job fires HOURS EARLY, then
`compute_next_run` advances it via croniter to `21:00+02:00` the same day,
producing a SECOND fire. (#28934, recurrence of #24289.)
`_get_due_jobs_locked` now detects this precise migration case before the
due check: for a `cron` job whose converted instant looks due, whose stored
UTC offset differs from the current zone's, AND whose stored *wall-clock*
time is still in the future (distinguishing a migrated offset from a
genuinely missed run), it recomputes `next_run_at` from the schedule and
skips the early fire — preserving the local wall-clock intent.
Verified against the issue's reproducer: stored `21:00+10` under runtime
`+02:00` at wall-clock `13:02` is rescheduled to `21:00+02` instead of
firing early + again.
Salvaged from #28941 by @Tranquil-Flow (authorship preserved). Chosen over
the alternative approaches (#28951 normalize-to-UTC, #28985 rebase-and-match)
because UTC-normalization does not change the absolute-instant comparison and
so does not fix the early fire, and this guard is the tightest: it only acts
when all four conditions hold and reuses the existing `compute_next_run`.
Fixes#28934
Remove unused imports (F401) and duplicate/shadowed import
redefinitions (F811) across the codebase using ruff's safe
autofixes. No behavioral changes -- imports only.
- ~1400 safe autofixes applied across 644 files (net -1072 lines)
- __init__.py re-exports preserved (excluded from F401 removal so
public re-export surfaces stay intact)
- Re-exports that are imported or monkeypatched by tests but look
unused in their defining module are kept with explicit # noqa:
F401 (gateway/run.py load_dotenv; run_agent re-exports from
agent.message_sanitization, agent.context_compressor,
agent.retry_utils, agent.prompt_builder, agent.process_bootstrap,
agent.codex_responses_adapter)
- Unsafe F841 (unused-variable) fixes deliberately skipped -- those
can change behavior when the RHS has side effects
- ruff lints remain disabled in pyproject.toml (only PLW1514 is
selected); this is a one-time cleanup, not a config change
Verification:
- python -m compileall: clean
- pytest --collect-only: all 27161 tests collect (zero import errors)
- core entry points import clean (run_agent, model_tools, cli,
toolsets, hermes_state, batch_runner, gateway)
- static scan: every name any test imports directly from an edited
module still resolves
Two defense-in-depth fixes on cron output path handling:
1. cron/jobs.py:update_job() rejects mutation of the immutable 'id' field
(raises ValueError). Dashboard PUT /api/cron/jobs/{id} converts this to
HTTP 400. Without this, an attacker who can reach the update endpoint
could rename a job's id to '../escape' and move its output directory
outside OUTPUT_DIR.
2. cron/jobs.py:_job_output_dir() validates job IDs before composing
paths: rejects '.', '..', '/', '\\', absolute paths, and Windows drive
prefixes. Used by save_job_output() and remove_job() so legacy unsafe
IDs (from before this guard) fail closed rather than half-applying a
shutil.rmtree or output write outside the sandbox.
Tests:
- update_job rejects {'id': '../escape'} without renaming
- remove_job(legacy '../escape' id) raises ValueError without deleting
files outside OUTPUT_DIR or removing the job from the store
- save_job_output rejects '..', './escape', 'nested/escape',
absolute paths
- dashboard PUT /api/cron/jobs/{id} with {'id': '../escape'} returns
400, job list unchanged
Salvaged from PR #29826 by @zapabob. Simplified implementation:
- Dropped a 23-line _validate_job_output_id() helper using Path.parts
semantics. The inline check (path separators + dot-components +
is_absolute) is shorter and behaviorally identical.
- Dropped the secondary OUTPUT_DIR.resolve()/relative_to() check —
redundant once we reject any path separator at the input boundary.
- Dropped the _docs/2026-05-21_cron-output-path-hardening_codex.md
planning artifact (we don't check planning docs into the repo).
Co-authored-by: teknium1 <127238744+teknium1@users.noreply.github.com>
Cron mutation operations (run/pause/resume/remove) and 'hermes cron edit'
now accept a job name in addition to the hex ID, with case-insensitive
matching. Before this, 'hermes cron run my_job_name' died with
'Job with ID my_job_name not found' and forced the user to look up the
hex ID first.
The original PR matched by name but silently picked the first match when
two jobs shared a name. This version refuses to act on an ambiguous name
and surfaces every matching job (id, name, schedule, next_run_at) so the
caller can pick a specific ID.
- cron/jobs.py:
- get_job() stays ID-only (preserves existing call-site semantics for
web_server/api_server/curator/scheduler/test code that always passes
real IDs).
- resolve_job_ref() is the new name-or-ID resolver, used by pause/
resume/trigger/remove_job. Exact ID match wins over a name match
even if a different job's name happens to equal that ID. Ambiguous
name match raises AmbiguousJobReference with all candidate IDs.
- tools/cronjob_tools.py: dispatch site uses resolve_job_ref, surfaces
ambiguous matches as a structured error with the matching IDs.
- hermes_cli/cron.py: 'cron edit' uses resolve_job_ref so editing by
name works and ambiguous names are reported with IDs.
- tests/cron/test_jobs.py: new TestResolveJobRef covering ID match,
case-insensitive name match, ID-wins-over-name, ambiguous refusal,
and that pause/resume/trigger/remove all refuse on ambiguity.
Closes#2627
get_due_jobs() called load_jobs() and save_jobs() without holding
_jobs_file_lock, creating a race with the locked mark_job_run() and
advance_next_run(). Wrap get_due_jobs() with the lock (delegating to a
new _get_due_jobs_locked() inner function) so all load→modify→save
cycles are serialised. Add two regression tests: one verifying 3
concurrent mark_job_run() calls each land their correct last_status and
last_run_at without overwrites, and a stress test confirming 10 parallel
calls each increment their job's completed count to exactly 1.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Adds four regression tests guarding the bugfix in the previous commit:
- TestGetDueJobs::test_broken_cron_without_next_run_is_recovered exercises
cron schedules whose next_run_at was lost; expects compute_next_run to
repopulate it within get_due_jobs() rather than silently skipping the job.
- TestGetDueJobs::test_broken_interval_without_next_run_is_recovered does
the same for interval schedules.
- TestResolveOrigin::test_string_origin_is_tolerated and
test_non_dict_origin_is_tolerated confirm _resolve_origin() returns None
for legacy/hand-edited origins (string, list, int) instead of raising.
Co-Authored-By: Claude <noreply@anthropic.com>
If the gateway's Python env loses access to 'croniter' between when a
cron job was created and when mark_job_run() fires, compute_next_run()
returns None for cron schedules. mark_job_run() treated that as terminal
completion and wrote enabled=false, state=completed — turning a missing
runtime dep into a silent, permanent job-off.
That behaviour is safe for one-shot jobs but wrong for recurring ones. A
missing dep should surface as an error the user can see, not as successful
completion of a job that is about to stop firing.
mark_job_run() now only disables the job on next_run_at=None when the
schedule is one-shot. For recurring (cron/interval) schedules it keeps
enabled=true, sets state=error, and records last_error so the user can
see why the job isn't advancing. compute_next_run() also logs a warning
the first time cron+no-croniter hits, so the underlying cause is visible
in the gateway log.
Tests cover:
- recurring cron job stays enabled with state=error when HAS_CRONITER=False
- recurring interval stays enabled when compute_next_run returns None
- one-shot jobs still flip to enabled=false, state=completed (no regression)
Fixes#16265
_deliver_result() now returns Optional[str] — None on success, error
message on failure. All failure paths (unknown platform, platform
disabled, config load error, send failure, unresolvable target)
return descriptive error strings.
mark_job_run() gains delivery_error param, tracked as
last_delivery_error on the job — separate from agent execution errors.
A job where the agent succeeded but delivery failed shows
last_status='ok' + last_delivery_error='...'.
The cronjob list tool now surfaces last_delivery_error so agents and
users can see when cron outputs aren't arriving.
Inspired by PR #5863 (oxngon) — reimplemented with proper wiring.
Tests: 3 new mark_job_run tests + 6 new _deliver_result return tests.
When a gateway crashes mid-job execution (before mark_job_run can persist
the updated next_run_at), the job would fire again on every restart attempt
within the grace window. For a daily 6:15 AM job with a 2-hour grace,
rapidly restarting the gateway could trigger dozens of duplicate runs.
Fix: call advance_next_run() BEFORE run_job() in tick(). For recurring
jobs (cron/interval), this preemptively advances next_run_at to the next
future occurrence and persists it to disk. If the process then crashes
during execution, the job won't be considered due on restart.
One-shot jobs are left unchanged — they still retry on restart since
there's no future occurrence to advance to.
This changes the scheduler from at-least-once to at-most-once semantics
for recurring jobs, which is the correct tradeoff: missing one daily
message is far better than sending it dozens of times.
Replace hardcoded 120-second grace period with a dynamic window that
scales with the job's scheduling frequency (half the period, clamped
to [120s, 2h]). Daily jobs now catch up if missed by up to 2 hours
instead of being silently skipped after just 2 minutes.
When the gateway restarts after being down past a scheduled run time,
recurring jobs (cron/interval) were firing immediately because their
next_run_at was in the past. Now jobs more than 2 minutes late are
fast-forwarded to the next future occurrence instead.
- get_due_jobs() checks staleness for cron/interval jobs
- Stale jobs get next_run_at recomputed and saved
- Jobs within 2 minutes of their schedule still fire normally
- One-shot (once) jobs are unaffected — they fire if missed
Fixes the 'cron jobs run on every gateway restart' issue.
Authored by areu01or00. Adds timezone support via hermes_time.now() helper
with IANA timezone resolution (HERMES_TIMEZONE env → config.yaml → server-local).
Updates system prompt timestamp, cron scheduling, and execute_code sandbox TZ
injection. Includes config migration (v4→v5) and comprehensive test coverage.