Commit graph

145 commits

Author SHA1 Message Date
Brooklyn Nicholson
70292596ef feat(browser): auto-install Chromium binary on local cold-start failure
When a local browser_navigate (or any browser command) fails fast because
Chromium isn't on disk, attempt a one-shot binary download via
`agent-browser install` and retry instead of only printing a hint.

Scope is narrow on purpose:
- binary only, never `--with-deps` (that shells apt/needs root, so missing
  system libraries stay a user action)
- gated by `security.allow_lazy_installs` (same opt-out as every lazy install)
- skipped in Docker (Chromium ships in the image)
- attempted once per process

Follow-up to #54353, which made the cold-start failure legible; this closes
the "doesn't actually install the missing browser" gap for the common case.
2026-06-28 12:25:15 -05:00
Brooklyn Nicholson
1ab5c3cdda refactor(browser): drop redundant sandbox-hint substring check 2026-06-28 12:14:47 -05:00
infinitycrew39
a10727a555 fix(browser): extend first-open timeout and surface daemon errors
Local browser_navigate cold-starts the agent-browser daemon and Chromium;
60s was too short on slow Linux hosts and timeouts discarded stderr,
leaving users with a generic failure. Use a 120s floor on first open,
inject --no-sandbox in Docker, include captured daemon output plus install
hints when commands time out, and show "Failed to open" in the desktop
tool chip when navigation returns success=false.
2026-06-28 12:14:21 -05:00
teknium1
7ef04ae7a7 fix(browser): close eval return-value SSRF bypass (sibling of #44731)
The snapshot/vision guards re-check the page URL before returning content,
but browser_console(expression=...) -> _browser_eval returns arbitrary JS
results directly, leaving two same-class bypasses open:

  1. Direct fetch: fetch('http://127.0.0.1/secret').then(r=>r.text()) reads
     a private endpoint and returns the body — the page URL stays public so
     the post-eval recheck never sees it.
  2. Navigate-then-read: location.href='http://127.0.0.1/' then a later eval
     reads document.body.innerText.

Guard _browser_eval on the same condition as navigate/snapshot/vision
(not local backend, not local sidecar, not allow_private_urls):
  - pre-scan the expression for private/always-blocked URL literals
  - re-check window.location.href after the eval at both success-return
    sites (supervisor fast-path + subprocess fallback)

Probe failures fail-open (matching the snapshot/vision guards).
2026-06-28 02:42:01 -07:00
liuhao1024
0ae6196087 fix(browser): allow local sidecar sessions to bypass SSRF guard
The private-network guard in browser_snapshot() and browser_vision()
blocked all private URLs, including those accessed via local sidecar
sessions (hybrid routing). Local sidecar sessions intentionally access
private URLs — the cloud provider never sees the URL in that case.

Add `_is_local_sidecar_key(effective_task_id)` check to both guards,
matching the existing pattern in browser_navigate().

Fixes #45101 review feedback from egilewski.
2026-06-28 02:42:01 -07:00
liuhao1024
48f5c42599 fix(browser): extend private-network guard to browser_vision
The SSRF bypass in #44731 was only patched for browser_snapshot(), but
browser_vision() exposes the same vulnerability — it takes a screenshot
and sends it to the vision model without checking if eval-driven
navigation moved the page to a private/internal URL.

Add the same current-page URL safety check to browser_vision() before
any screenshot is captured, encoded, or forwarded to the vision model.
This covers both the normal screenshot path and the Lightpanda Chrome
fallback path.

7 new tests: blocks private URL, allows public URL, skips in local
backend, skips when private URLs allowed, handles eval failure/empty/exception.
2026-06-28 02:42:01 -07:00
liuhao1024
7a6fe9bbfa fix(browser): block snapshot from eval-navigated private pages
browser_snapshot() now checks the current page URL before returning
content. When browser_console() changes location.href to a private or
internal address (e.g., http://127.0.0.1:8080/), the snapshot returns
an error instead of exposing the private page content.

This closes the SSRF bypass where an attacker could:
1. Navigate to a public page
2. Use browser_console to eval location.href = 'http://127.0.0.1:port/'
3. Use browser_snapshot to read the private page content

The fix reuses the existing _is_safe_url() and _allow_private_urls()
infrastructure, and fails open if the URL check itself fails.

Fixes #44731
2026-06-28 02:42:01 -07:00
teknium1
8c8967a50b fix: defer hermes_subprocess_env import in browser_tool
The module-level import broke tests/tools/test_managed_browserbase_and_modal.py,
which loads browser_tool.py via spec_from_file_location against a stubbed
'tools' package that does not include tools.environments.local. Move the import
into a _build_browser_env() helper called at the two agent-browser spawn sites,
matching the lazy-import pattern already used by lazy_deps.py.
2026-06-27 20:45:31 -07:00
teknium1
9c6229ce24 fix(security): centralize credential-safe subprocess env (#29157)
Subprocesses spawned outside the terminal/execute_code path (agent-browser,
copilot ACP, dep-ensure, lazy_deps uv install, TUI Node host, cli.exec)
inherited the operator's full credential environment via os.environ.copy().
The terminal path was already scrubbed by _HERMES_PROVIDER_ENV_BLOCKLIST
(#1002/#1264/#32314); these spawn sites bypassed it.

Adds hermes_subprocess_env(inherit_credentials=) in tools/environments/local.py
reusing the existing dynamic blocklist as the single source of truth:

  - Tier 1 (_ALWAYS_STRIP_KEYS): gateway bot tokens, GitHub auth, infra
    secrets -- stripped even for credential-inheriting children.
  - Tier 2 (_HERMES_PROVIDER_ENV_BLOCKLIST): provider/tool keys -- stripped
    unless inherit_credentials=True. The opt-in is grep-able for audit.

Browser worker keeps a _BROWSER_PASSTHROUGH_KEYS allowlist (BROWSERBASE/
FIRECRAWL) re-added after the strip. Model-driving children (ACP, TUI Node
host, cli.exec) use inherit_credentials=True so they still get provider keys
while losing Tier-1 secrets. Installers (dep-ensure, lazy_deps) inherit
nothing sensitive. cua_backend already routed through _sanitize_subprocess_env
on main -- left as-is. Gateway adapter utility spawns (gh pr comment, ffmpeg)
are left inheriting env: gh needs GH_TOKEN by design, ffmpeg is a trusted
system binary -- no untrusted-dependency exposure.

This is defense-in-depth (personal-assistant trust model: same-user spawns),
making the existing scrub policy uniform across the spawn surface; the main
real payoff is shrinking the blast radius if a transitive npm dep in
agent-browser is compromised.

Reconstructed on current main from the design in #31959 (Tranquil-Flow);
also credits #39003 (rodboev), #37843 (coygeek), #35769 (egilewski).

Co-authored-by: Tranquil-Flow <tranquil_flow@protonmail.com>
Co-authored-by: rodboev <rod.boev@gmail.com>
Co-authored-by: egilewski <egilewski@egilewski.com>
2026-06-27 20:45:31 -07:00
Teknium
d3d621f7c3
revert(windows): roll back terminal-popup PRs #53791 #53810 #53829 (#53853)
* Revert "fix(windows): capture is not a no-window boundary; route flashing spawns through chokepoint (#53829)"

This reverts commit 2ecca1e7d3.

* Revert "fix(windows): stop terminal-window popups from background spawns (#53810)"

This reverts commit 5db1430af9.

* Revert "fix(windows): stop subprocess console-window popups + add CI guard (#53791)"

This reverts commit ef17cd204d.
2026-06-27 15:59:00 -07:00
brooklyn!
5db1430af9
fix(windows): stop terminal-window popups from background spawns (#53810)
* fix(windows): stop terminal-window popups from background spawns

Native-Windows desktop/gateway users saw cmd/conhost windows flash on
gateway restart, image paste, the dashboard Projects tree, voice notes,
and ~5 min after closing the app (detached cron). Two root causes:

- Console-subsystem exes (taskkill, schtasks, wmic, netstat, tasklist,
  agent-browser, git, ffmpeg, powershell, git-bash) spawned via raw
  subprocess allocate a fresh console when the launching process has
  none (pythonw desktop backend / detached gateway) - even with output
  captured.
- uv venv pythonw shims re-exec console python.exe, so Python children
  get a console regardless of how they're launched.

Fixes:
- Single hidden-spawn primitive (_subprocess_compat.run/.popen) that ORs
  CREATE_NO_WINDOW on Windows, no-op on POSIX. Route every Hermes-owned
  console-exe spawn through it.
- FreeConsole() catch-all in hermes_bootstrap: any Python child that
  exclusively owns an auto-allocated console detaches it at startup
  (GetConsoleProcessList()==1 gate leaves shared interactive consoles
  untouched).
- Replace PowerShell/wmic gateway PID scans with in-process psutil.
- Skip schtasks queries on non-interactive desktop restarts.
- Prefer native agent-browser .exe over .cmd shims.
- Guard test bans raw subprocess spawns of the Windows-only console
  tools repo-wide so the popup class can't regress.

* fix(windows): scope FreeConsole to background entry points; fix merge fallout

Console detach review (per #53810 feedback): GetConsoleProcessList()==1 can't
tell a uv pythonw->python phantom console apart from a user opening the
interactive CLI/TUI in its own fresh console (double-click, shortcut, ConPTY) —
both report a single attached process with a tty. Running FreeConsole() in the
import-time bootstrap therefore risked detaching a legitimately-interactive
terminal.

- Extract FreeConsole into explicit hermes_bootstrap.detach_orphan_console();
  remove it from apply_windows_utf8_bootstrap() (import side effect).
- Call it only from known background mains: gateway run, dashboard backend
  (start_server, what the desktop spawns), cron standalone, tui_gateway entry,
  slash worker. Interactive CLI/TUI never calls it.
- Behavior-contract tests: frees only when solo owner, leaves shared console,
  no-op without console / on POSIX, and asserts it's not an import side effect.

Merge fallout from origin/main (#53791):
- local.py: 3-way merge left a dangling **_popen_kwargs (NameError crashing
  every terminal init). _subprocess_compat.popen already hides the window, so
  drop it.
- discord adapter: merge stacked an undefined windows_hide_flags() onto the
  primitive call; drop the redundant arg.
- test_gateway: scan now goes psutil-first (zero spawn); rewrite the
  case-variant test to drive that production path.

* test(claw): mock _subprocess_compat.run seam for Windows process scan

claw.py's Windows tasklist/powershell scan routes through the hidden-spawn
primitive; the tests still patched claw_mod.subprocess, so on win32 the mock
was never hit and real spawns returned nothing. Patch the actual seam.
2026-06-27 14:02:24 -07:00
teknium1
6c58878e7d fix(browser): force secret-pattern redaction on browser_type display
Force redact_sensitive_text(force=True) on the browser_type text arg so
recognized credentials (API keys, tokens, JWTs) are masked in tool
progress, previews, callbacks, and return payloads even when the global
security.redact_secrets opt-out is set — a typed credential reaching chat
history is a security boundary, not log hygiene. Normal typed text matches
no pattern and stays fully readable for debuggability.

Tests assert the API-key-shaped secret is masked across every surface and
that normal text passes through unchanged.
2026-06-25 22:02:22 -07:00
rebel
8ff426e53b fix: redact browser typed text surfaces 2026-06-25 22:02:22 -07:00
Gille
e7d2f0b93c fix(windows): suppress console flashes and harden gateway restarts 2026-06-25 14:42:38 -07:00
Teknium
3c75e11571
fix(browser): validate agent-browser is runnable, not just present (#51740)
After `hermes update`, a globally-installed agent-browser's npm postinstall
(fixUnixSymlink) re-points the global symlink (e.g. /opt/homebrew/bin/agent-browser)
at our local node_modules binary. The next update wipes node_modules, leaving a
dangling symlink that `which` still reports but exec fails on with exit 127 —
silently breaking every browser tool (#48521).

Root cause is trust-on-presence: shutil.which/Path.exists accept a name that
resolves but won't run. Add hermes_constants.agent_browser_runnable() (resolves
the path + runs --version) and gate all four resolution sites on it:
_find_agent_browser now skips a dead candidate and falls through to the next
working one (extended PATH -> local .bin -> npx), self-healing the dangling link.
dep_ensure/doctor/nous_subscription validate too; doctor warns on a broken link.

Closes #48521.
2026-06-24 00:14:49 -07:00
teknium1
624580e836 fix(browser): verify daemon identity before orphan reaper kills a PID (#14073)
The browser orphan reaper reads a daemon PID from a `.pid` file in a
world-writable, predictably-named temp dir (`/tmp/agent-browser-h_*`) it
does not write itself, then tree-kills that PID via `_terminate_host_pid`
after only a liveness check. A same-user actor could plant a fake socket
dir whose `.pid` points at an arbitrary victim process, and OS PID reuse
after the real daemon exits could land the recorded PID on an unrelated
process — either way an arbitrary same-user process (and its whole tree)
gets SIGTERMed. Local DoS.

Add `_verify_reapable_browser_daemon()`, gated before the kill: via psutil
(a hard dep, fine cross-platform for the same-user processes the reaper can
signal) require both (1) identity — `agent-browser` in the process
name/cmdline — and (2) binding — the live process references *this* session's
socket dir in its cmdline or `AGENT_BROWSER_SOCKET_DIR`. The binding check is
the real spoof defense: a planted/recycled PID won't embed our exact socket
path. Fail-closed on any ambiguity (unreadable cmdline, no match), leaving the
process and its socket dir untouched for a later sweep.

Builds on @sgaofen's fix in #14394 (cmdline identity check); rewritten to use
psutil instead of `/proc`+`ps` (cross-platform, Windows-covered) and to add
the session-socket-dir binding check for recycled-PID / spoof resistance.

Co-authored-by: sgaofen <135070653+sgaofen@users.noreply.github.com>
2026-06-21 15:23:47 -07:00
liuhao1024
6984026f12 fix(browser): enable SSRF guard when terminal runs in container
When terminal.backend is docker/modal/daytona/ssh/singularity, the
terminal runs in a sandboxed container with network isolation, but the
browser still runs on the host.  The SSRF guard was skipped because
_is_local_backend() only checked browser.cloud_provider, not the
terminal backend.

Now _is_local_backend() also checks TERMINAL_ENV — when the terminal
is containerized, the browser is treated as non-local and SSRF
protection is enabled.

Fixes #38690
2026-06-21 07:26:18 -07:00
Teknium
3e7e9b24d4 fix: harden salvaged session and browser improvements
Polish salvaged contributor work before PR review:
- read browser inactivity timeout from config with documented fallback
- skip redundant v10 trigram backfill before v11 FTS rebuild
- show delegate_task goals safely in progress previews
- show gateway status model/context without redundant token wording
- wire gateway /sessions to shared session-listing helpers
- map Ravenwolf author emails for release attribution

Co-authored-by: Wolfram Ravenwolf <github.com@wolfram.ravenwolf.de>
Co-authored-by: Amy Ravenwolf <amy@ravenwolf.de>
2026-06-15 07:46:34 -07:00
Amy Ravenwolf
2f2e3616b4 fix(config): read browser inactivity timeout from config 2026-06-15 07:46:34 -07:00
helix4u
333f01bc7f fix(tools): percent-encode non-ascii URL components 2026-06-07 11:42:26 -06:00
Teknium
2912d94370
fix: guard int(os.getenv()) casts against malformed env vars (#40598)
A non-numeric value in env vars like HERMES_STREAM_RETRIES,
HERMES_KANBAN_SPECIFY_MAX_TOKENS, GOOGLE_CHAT_MAX_BYTES, IRC_PORT, etc.
raised ValueError at import/init and crashed startup. Parse them safely,
falling back to the default.

Unified onto the existing utils.env_int(key, default) helper for core/
hermes_cli/tools modules instead of the original PR's three duplicate
local helpers; plugins keep minimal inline guards (no core-utils import).
All existing max()/min()/`or extra.get()` wrappers preserved.

Co-authored-by: annguyenNous <annguyenNous@users.noreply.github.com>
2026-06-07 06:14:24 -07:00
Teknium
92ad7cc62c
fix(browser): recover from CDP DOM-node serialization crash in browser_console (#35385)
browser_console(expression="document.body") returned the cryptic CDP error
"Object reference chain is too long" instead of a usable result.

With returnByValue=true, Chrome deep-serializes the eval result; for a live
DOM Node/NodeList/Window that serialization overruns CDP's recursion guard
and fails the whole call with a protocol-level error (not a JS exception),
which _browser_eval surfaced raw.

- browser_supervisor.evaluate_runtime: on that specific error, retry once
  with returnByValue=false so Chrome returns the node's description string —
  the same graceful path already used for document.querySelector() results.
- browser_tool._browser_eval (CLI subprocess fallback): the subprocess can't
  retry, so convert the reference-chain error into actionable guidance
  (extract a primitive / use JSON.stringify) instead of leaking it raw.

No expression rewriting — normal evals (1+41 -> 42) are untouched.
2026-05-30 07:31:25 -07:00
kurobaryo
03bdeaa876 docs: fix BROWSERBASE_SESSION_TIMEOUT unit (ms → seconds) 2026-05-29 12:06:22 -07:00
teknium1
c77a697fa4 refactor(vision): consolidate native fast-path gate into one shared helper
The fast-path decision (native routing + provider allowlist OR
supports_vision override) lived inline in vision_analyze and was copied
into browser_vision. Extract it to _should_use_native_vision_fast_path()
so both tools share one source of truth.

- vision_tools: gate logic now one helper; vision_analyze calls it in 3 lines
- browser_tool: thin envelope decoration over the shared helper, not a copy
- browser_vision typed Union[str, Dict] to match its real return shape
- tests slimmed to target the override path + text-mode-wins invariant
2026-05-29 03:58:56 -07:00
tillfalko
c3f28c651d docs(browser): update browser_vision tool description for native vision routing 2026-05-29 03:58:56 -07:00
tillfalko
f8b8dffccf fix(browser): add native image support to browser_vision and respect supports_vision 2026-05-29 03:58:56 -07:00
kshitijk4poor
66827f8947 chore: prune unused imports and duplicate import redefinitions
Remove unused imports (F401) and duplicate/shadowed import
redefinitions (F811) across the codebase using ruff's safe
autofixes. No behavioral changes -- imports only.

- ~1400 safe autofixes applied across 644 files (net -1072 lines)
- __init__.py re-exports preserved (excluded from F401 removal so
  public re-export surfaces stay intact)
- Re-exports that are imported or monkeypatched by tests but look
  unused in their defining module are kept with explicit # noqa:
  F401 (gateway/run.py load_dotenv; run_agent re-exports from
  agent.message_sanitization, agent.context_compressor,
  agent.retry_utils, agent.prompt_builder, agent.process_bootstrap,
  agent.codex_responses_adapter)
- Unsafe F841 (unused-variable) fixes deliberately skipped -- those
  can change behavior when the RHS has side effects
- ruff lints remain disabled in pyproject.toml (only PLW1514 is
  selected); this is a one-time cleanup, not a config change

Verification:
- python -m compileall: clean
- pytest --collect-only: all 27161 tests collect (zero import errors)
- core entry points import clean (run_agent, model_tools, cli,
  toolsets, hermes_state, batch_runner, gateway)
- static scan: every name any test imports directly from an edited
  module still resolves
2026-05-28 22:26:25 -07:00
Teknium
3d66787a04
fix(vision): route auxiliary.vision.provider=openai to api.openai.com, skip text-only main (#31452)
* fix(vision): route auxiliary.vision.provider=openai to api.openai.com, skip text-only main for vision

Fixes #31179. Three coupled fixes so a configured aux vision backend
actually serves vision tasks instead of silently routing images to the
user's main provider:

1. agent/auxiliary_client.py: `auxiliary.<task>.provider: openai` resolves
   to `custom` + `https://api.openai.com/v1`. "openai" was not in
   PROVIDER_REGISTRY (we have `openai-codex` for OAuth and `custom` for
   manual base_url), so the obvious config name silently failed to build a
   client. User-supplied base_url is still preserved; only the provider
   name normalises to `custom` so resolution doesn't hit the
   PROVIDER_REGISTRY-only path.

2. agent/auxiliary_client.py: the vision auto-detect chain now skips the
   user's main provider when models.dev reports `supports_vision=False`.
   Without this guard, a misconfigured aux provider would fall back to
   `auto`, which happily returned the main-provider client. The caller
   would then send image content to e.g. api.deepseek.com with model
   `gpt-4o-mini` and get a cryptic `unknown variant 'image_url',
   expected 'text'` from the provider's parser.

3. tools/vision_tools.py + tools/browser_tool.py: `check_vision_requirements`
   now mirrors the runtime fallback chain (explicit provider, then auto),
   so `vision_analyze` shows up whenever vision is actually serviceable.
   `browser_vision` gets a new `check_browser_vision_requirements` check_fn
   that AND-gates browser + vision availability, so it doesn't get
   advertised to the model when the call would fail at runtime.

Reproduction (config from the bug report):
  model.provider: deepseek
  model.default: deepseek-v4-pro
  auxiliary.vision.provider: openai
  auxiliary.vision.model: gpt-4o-mini

Before: resolve_vision_provider_client() returns None for the explicit
provider, fallback auto returns the deepseek client with model='gpt-4o-mini',
image hits api.deepseek.com → 'unknown variant image_url'. vision_analyze
hidden from tool list; browser_vision exposed but fails at call time.

After: resolves to custom + api.openai.com/v1 with model gpt-4o-mini.
vision_analyze and browser_vision both gate correctly on capability.

Tests: tests/agent/test_vision_routing_31179.py covers all three fixes
(12 cases including the user's exact scenario, base_url preservation,
text-only-main skip, capability-unknown permissive fallback, and tool
gating parity). Existing 382 tests across auxiliary/vision/image_routing
suites still pass.

* test(vision): use exact hostname check to silence CodeQL substring-sanitization alert

* fix(auxiliary): drop model name from vision-skip debug log to silence CodeQL

The new `logger.debug(...)` added in the previous commit interpolated
both `main_provider` and `vision_model` (a public model slug \u2014 not
sensitive). CodeQL's `py/clear-text-logging-sensitive-data` heuristic
re-flagged it twice because the rule mis-detects multi-value
interpolations near tainted-via-config provider strings.

Drop the model from the log args (provider alone is enough to diagnose
the skip; the same sibling branch a few lines up already logs provider
only). Behavior unchanged; CodeQL false positive cleared.
2026-05-24 15:01:28 -07:00
Yuan Li
22f3f5a75a fix(browser): use process-tree termination for daemon cleanup
os.kill(pid, SIGTERM) only signals the parent, leaving Chromium child
    processes (renderer, GPU, etc.) orphaned.  Reuse the existing
    ProcessRegistry._terminate_host_pid() helper which walks the process
    tree leaf-up via psutil, terminating children before the parent.
2026-05-23 20:30:29 -07:00
Siddharth Balyan
e3a254d65b
feat(dep_ensure): complete Windows bootstrap — dep_ensure + install.ps1 + detection (#27845)
* feat(dep_ensure): complete Windows bootstrap — dep_ensure + install.ps1 + detection

dep_ensure.py gains Windows awareness: PowerShell invocation, platform-
specific browser detection, (path, shell) tuple returns.

install.ps1 gains -Ensure/-PostInstall modes using npm -g --prefix
(aligned with install.sh) and agent-browser install for Chromium.

browser_tool.py gains node/ in candidate dirs for Windows .cmd shims.
Both install scripts bundled in pip wheel.

Tracking: #27826

* fix(install.ps1): add --ignore-scripts to npm install for camofox

@askjo/camofox-browser has a dependency (impit) whose postinstall
script runs `npx only-allow pnpm`, which fails under npm. Adding
--ignore-scripts avoids the spurious failure without affecting
functionality.

Tracking: #27826

* fix: remove duplicate install scripts from git

CI already copies scripts/install.{sh,ps1} into hermes_cli/scripts/
during wheel build. No need to commit copies — .gitignore keeps them
out, _find_install_script() falls back to scripts/ for git-clone users.

Tracking: #27826

* fix: address review — remove env_extra, fix ps1 error handling

- Remove unused env_extra parameter from ensure_dependency()
- Invoke-EnsureMode node case now uses Test-Node consistently
- Install-AgentBrowser uses throw instead of exit 1
2026-05-18 16:34:24 +05:30
kshitijk4poor
c74ff2c8ef fix(browser): self-review pass — dead-import, log levels, future-proofing
Addresses findings from two self-review passes pre-merge.

First pass (3-agent parallel review):

1. plugins/browser/browser_use/provider.py: drop the
   ``_ = managed_nous_tools_enabled`` dead-import-hider in
   _get_config_or_none(). The import was actively misleading — the
   helper IS used in _get_config() (separate method, separate import),
   not here. The "keep static analysis happy" comment was wrong about
   what the helper does in this scope.

2. agent/browser_provider.py: drop ``pragma: no cover`` from
   is_configured() / provider_name() backward-compat aliases. They ARE
   covered by ``TestLegacyAbcAliases`` — the pragma would have masked
   future regressions.

3. tools/browser_tool.py: refactor _is_legacy_provider_registry_overridden()
   to compare against a module-frozen _DEFAULT_PROVIDER_REGISTRY snapshot
   instead of hardcoded set of 3 keys. Future maintainers adding a 4th
   built-in provider now just extend _PROVIDER_REGISTRY; the override
   detection adapts automatically. Previously the hardcoded
   ``set(...) != {"browserbase", "browser-use", "firecrawl"}`` would flip
   True forever on any 4-key registry, silently routing every install
   onto the legacy fixture path.

4. tools/browser_tool.py: when explicit ``browser.cloud_provider`` is set
   but the registry has no matching plugin (typo, uninstalled plugin,
   discovery failure), emit a WARNING with actionable text instead of
   silently falling through to auto-detect. Legacy code surfaced a typed
   credentials error via direct class instantiation; this log restores
   the signal in the post-migration path.

5. agent/browser_registry.py: trim the triple-redundant _LEGACY_PREFERENCE
   documentation. Module docstring + 13-line block-comment + 5-line
   inline comment was repeating the same point. Kept the docstring and
   trimmed the block-comment to 5 lines.

6. agent/browser_registry.py: upgrade is_available()-raised logging from
   DEBUG to WARNING with exc_info=True. A provider's availability check
   throwing is unusual enough that users debugging "no cloud provider"
   need the traceback in logs.

7. tests/plugins/browser/check_parity_vs_main.py: drop dead top-level
   imports (os, shutil, tempfile — only referenced inside the
   SUBPROCESS_SCRIPT string literal that runs in a child process).

Second pass (architecture + claim-verification review):

8. tools/browser_tool.py: rewrite the inline comment in _get_cloud_provider
   auto-detect branch. Prior text claimed it "routes through the plugin
   registry's legacy preference walk so third-party plugins still get a
   chance to be selected when they're explicitly configured" — false on
   both counts. The branch uses module-level legacy class aliases
   (BrowserUseProvider / BrowserbaseProvider) directly; third-party
   plugins are intentionally reachable only via explicit
   ``browser.cloud_provider``. Corrected comment now matches behaviour
   and cross-references _LEGACY_PREFERENCE for the firecrawl gate
   rationale.

9. tools/browser_tool.py + tests/tools/test_managed_browserbase_and_modal.py:
   drop the unused ``get_active_browser_provider as
   _registry_get_active_browser_provider`` alias from the
   ``from agent.browser_registry import ...`` block. It was never
   referenced; matching test-stub line in the agent.browser_registry
   SimpleNamespace also dropped. ``get_provider`` is still imported (used
   by the explicit-config dispatch path at line 535).

10. plugins/browser/firecrawl/provider.py: align emergency_cleanup()
    with the early-guard pattern used in browserbase + browser_use
    plugins. Previously firecrawl tried the DELETE and relied on
    ``_headers()`` raising ValueError to trip a "missing credentials"
    warning; same final outcome but a different control flow that read
    like a bug to a maintainer skimming the three modules. Now: if
    is_available() is False, log+return early — identical shape to the
    other two providers.

Verification: 54/54 unit tests + 13/13 parity scenarios still pass.
2026-05-17 04:04:15 -07:00
kshitijk4poor
1bb6f03724 fix(browser): ensure plugin discovery before registry lookup; parity harness
Two changes that go together:

1. tools/browser_tool.py — add _ensure_browser_plugins_loaded() and call
   it from _get_cloud_provider() before consulting the registry. Normally
   model_tools triggers discover_plugins() as an import side-effect, but
   _get_cloud_provider() can be reached from contexts that haven't gone
   through model_tools (standalone scripts, certain unit-test paths, the
   new parity-sweep harness). Without the defensive call, the registry is
   empty and _registry_get_browser_provider() returns None — silently
   downgrading users to local mode when they explicitly configured a
   cloud provider with no credentials yet. The behavior-parity sweep
   below caught this as 4 scenario regressions (explicit-X-no-creds for
   all 3 providers, and explicit-firecrawl-with-creds).

2. tests/plugins/browser/check_parity_vs_main.py — subprocess harness
   that pins one Python invocation to origin/main and one to this PR's
   worktree via sys.path.insert(), runs _get_cloud_provider() across a
   13-scenario config matrix, and diffs the reduced shape tuple
   (is_local, provider_name, is_available). Provider_name pulls from
   provider.provider_name() which is the legacy CloudBrowserProvider
   API and remains as a backward-compat alias on the new BrowserProvider
   ABC, so the comparison is apples-to-apples regardless of class
   identity.

Final result: PARITY OK across 13 scenarios. The four observable
config/credential matrices that exercise the dispatcher all match
origin/main bit-for-bit:

  - no-config + no-env → local
  - explicit local + any env → local
  - explicit BB / BU / FC + no creds → provider returned with
    is_available()==False (so dispatcher surfaces typed credentials
    error; matches main exactly)
  - explicit BB / BU / FC + creds → provider returned with
    is_available()==True
  - no-config + BU creds → Browser Use
  - no-config + BB creds → Browserbase
  - no-config + both → Browser Use (legacy walk first hit)
  - no-config + FC only → local (firecrawl NOT in legacy walk)
  - no-config + FC + BB → Browserbase (legacy walk skips firecrawl)

Per the dev skill's "behavior-parity for refactor PRs" rule — without
this subprocess sweep, 31/31 unit tests pass while the production code
path is silently broken for users who type `browser.cloud_provider:
browserbase` and run a single browser command without prior model_tools
import. Caught + fixed before push.
2026-05-17 04:04:15 -07:00
kshitijk4poor
40fde853fa refactor(browser): dispatch _get_cloud_provider through agent.browser_registry
Switches tools.browser_tool's cloud-provider lookup from the hardcoded
_PROVIDER_REGISTRY class-instantiation pattern to the
agent.browser_registry singleton registry that plugins self-populate.

Changes:

- tools/browser_tool.py top imports: pull BrowserProvider from
  agent.browser_provider (re-exported as CloudBrowserProvider for legacy
  callers) and the three provider classes from plugins/browser/<vendor>/.
  Legacy class names (BrowserbaseProvider, BrowserUseProvider, FirecrawlProvider)
  remain on tools.browser_tool as re-export shims so existing test patches
  (monkeypatch.setattr(browser_tool, 'BrowserUseProvider', ...)) keep working.

- _get_cloud_provider() now consults agent.browser_registry.get_provider()
  for explicit-config lookups. The auto-detect fallback still uses
  BrowserUseProvider() / BrowserbaseProvider() at the module level so the
  cache-policy test fixtures (which patch those names) keep driving the
  function. Test-time _PROVIDER_REGISTRY overrides are detected by class
  identity and routed through the legacy factory-call path.

- agent/browser_provider.py: BrowserProvider grows is_configured() and
  provider_name() as thin backward-compat aliases for the legacy
  CloudBrowserProvider API. Subclasses MUST implement is_available() and
  name; the aliases delegate. This keeps ~6 caller sites in browser_tool.py
  working without churning them.

- tests/tools/test_managed_browserbase_and_modal.py: _install_fake_tools_package
  grows stubs for agent.browser_provider / agent.browser_registry /
  plugins.browser.<vendor>.provider so the test's spec-loader path
  (sys.modules-reset + reload-tool-from-disk) can satisfy tools.browser_tool's
  top-level imports.

Verified: all 23 existing tests in test_browser_cloud_*.py +
test_managed_browserbase_and_modal.py still pass post-cutover.

The legacy tools/browser_providers/ directory is NOT yet deleted; several
tests still _load_tool_module() those files via spec_from_file_location.
The deletion + test-path updates land in a later commit.
2026-05-17 04:04:15 -07:00
alt-glitch
c57709a3d6 feat: wire ensure_dependency into TUI and browser tool call sites
Before: missing node → hard exit; missing browser → FileNotFoundError.
After: both try ensure_dependency() first, which prompts interactively
and delegates installation to install.sh --ensure.

ripgrep and ffmpeg already degrade gracefully (grep fallback, skip
conversion) so they don't need wiring.

Also documents the design rationale in dep_ensure.py: detection and
prompting live in Python (portable, instant, UX-integrated); only
the actual installation delegates to install.sh (1900 lines of
battle-tested OS/package-manager logic).
2026-05-15 14:45:43 -07:00
alt-glitch
259ae846c8 feat: add ensure_dependency() wrapper + ship install.sh in wheel
Includes paired change: browser tool now searches ~/.hermes/node_modules/.bin/
for agent-browser installed via install.sh --ensure browser.
2026-05-15 14:45:43 -07:00
teknium1
4695d2716f fix(browser): honor pre-set AGENT_BROWSER_ARGS and document the bypass
Follow-up to the sandbox-bypass env-var fix:

- Update the opt-out gate so a user-provided AGENT_BROWSER_ARGS is also
  respected, not just the legacy AGENT_BROWSER_CHROME_FLAGS. Previously
  the gate only checked the broken legacy var, so a user who pre-set
  AGENT_BROWSER_ARGS would still get clobbered by Hermes's auto-injection.
- Document AGENT_BROWSER_ARGS in .env.example, the browser feature page,
  and the env var reference, with notes about the auto-injection on
  AppArmor-restricted systems (Ubuntu 23.10+, DGX Spark, containers).
- Add Anadi Jaggia to AUTHOR_MAP.
2026-05-14 19:02:17 -07:00
Anadi Jaggia
8ed2ef6f46 fix(browser): use correct env var for --no-sandbox bypass
AGENT_BROWSER_CHROME_FLAGS is not read by agent-browser CLI.
The correct env var is AGENT_BROWSER_ARGS, with comma-separated values.

This fixes Chrome 'No usable sandbox' crash on Ubuntu 23.10+ systems
where AppArmor restricts unprivileged user namespaces. The detection
logic was correct but the fix used the wrong environment variable name
and space-separated instead of comma-separated args.
2026-05-14 19:02:17 -07:00
helix4u
52521c937a fix(install): skip browser download when system chromium exists 2026-05-13 22:07:02 -07:00
kshitij
2ec8d2b42f
chore: ruff auto-fix PLR6201 — tuple → set in membership tests (#23937)
Replace  with  for all literal-tuple
membership tests. Set lookup is O(1) vs O(n) for tuple — consistent
micro-optimization across the codebase.

608 instances fixed via `ruff --fix --unsafe-fixes`, 0 remaining.
133 files, +626/-626 (net zero).
2026-05-11 11:13:25 -07:00
Teknium
d4b26df897
perf(browser): route browser_console eval through supervisor's persistent CDP WS (180x faster) (#23226)
Adds CDPSupervisor.evaluate_runtime() and wires it into _browser_eval as a
fast path when a supervisor is alive for the current task_id. Replaces the
~180ms agent-browser subprocess fork+exec+Node-startup hop with a ~1ms
Runtime.evaluate over the supervisor's already-connected WebSocket.

Falls through to the existing agent-browser CLI path when no supervisor is
running (e.g. backends without CDP, or before the first browser_navigate
attaches one), so behaviour is unchanged where it can't apply.

JS-side exceptions surface directly without falling through to the
subprocess (the subprocess would just re-raise the same error, slower);
supervisor-side failures (loop down, no session) fall through cleanly.

Benchmark — 30 iterations of `1 + 1` against headless Chrome:
  supervisor WS              mean=  0.96ms  median=  0.91ms
  agent-browser subprocess   mean=179.35ms  median=167.73ms
  → 187x speedup mean

Tests: 14 unit tests (mocked supervisor + response-shape coverage), 5
real-Chrome e2e tests in test_browser_supervisor.py (gated on Chrome
being installed). Browser test suite: 355 passed, 1 skipped.
2026-05-10 07:37:55 -07:00
Wesley Simplicio
48bf0ea249 fix(browser_tool): fall through to autodetect on config read failure 2026-05-09 13:35:39 -07:00
Wesley Simplicio
3170c8d448 fix(browser_tool): do not cache transient None cloud provider resolution
Problem: `_get_cloud_provider()` set `_cloud_provider_resolved = True`
before resolution. If credentials were briefly unavailable on the first
call (e.g. a managed Nous Portal token mid-refresh), the resolver pinned
the entire process to local mode forever, even after credentials
self-healed seconds later.

Root cause: bookkeeping was set up-front, so any code path that fell
through to `return _cached_cloud_provider` (config read failure, no
credentials yet, explicit-provider instantiation failure) committed the
transient `None` to the cache permanently.

Fix: invert the bookkeeping. `_cloud_provider_resolved = True` is now
set only when (a) the user explicitly chose `cloud_provider: local`, or
(b) a provider was successfully resolved. All transient `None` paths
return without poisoning the cache, so the next call retries. Explicit
provider instantiation failures now log at warning level with stack
trace so operators can diagnose them.

Tests: 5 new cases in tests/tools/test_browser_cloud_provider_cache.py
covering explicit local, successful resolution, no-credentials-yet,
config read failure, and explicit provider instantiation failure.
Stash-verify confirmed the 3 transient-None tests fail without the fix.
All 320 existing browser tests still green.

Closes #22324
2026-05-09 13:35:39 -07:00
Teknium
324567c936 fix(windows): os.kill(pid, 0) is NOT a no-op on Windows — route through new _pid_exists helper
On Windows, Python's ``os.kill(pid, 0)`` is NOT a no-op. CPython's
implementation (``Modules/posixmodule.c::os_kill_impl``) treats sig=0
as ``CTRL_C_EVENT`` because the two integer values collide at the C
layer, and routes it through ``GenerateConsoleCtrlEvent(0, pid)`` —
which sends a Ctrl+C to the ENTIRE console process group containing
the target PID, not just the PID itself. Any caller that wanted to
check "is PID X alive" via the classic POSIX ``os.kill(pid, 0)``
idiom was silently killing that process (and often unrelated
processes in the same console group) on Windows. Long-standing
Python Windows quirk; see bpo-14484 (open since 2012).

This manifested in Hermes as: every ``hermes gateway status``
invocation would read the gateway's PID from the PID file, call
``os.kill(pid, 0)`` via ``gateway.status.get_running_pid()`` as a
"liveness check", and instantly terminate the gateway it was trying
to report on. No shutdown log, no traceback, no atexit hook fire,
no exit-diag entry — just silent termination of the detached pythonw
process. "Bot answered one message then stopped typing" was the
characteristic end-user symptom because `os.kill(pid, 0)` fires
mid-response-send and kills the gateway between logs.

Reproduction (verified in this branch before the fix):

  $ hermes gateway start       # gateway alive, PID 37520
  $ hermes gateway status      # reports "No gateway process detected"
  $ tasklist /FI "PID eq 37520"  # INFO: No tasks are running
                                 # — gateway terminated silently

Root-cause fix is a new ``gateway.status._pid_exists(pid)`` helper:

- On Windows: Win32 ``OpenProcess(PROCESS_QUERY_LIMITED_INFORMATION |
  SYNCHRONIZE, False, pid)`` + ``WaitForSingleObject(handle, 0)``
  via ctypes. Zero signal delivery, zero console-group side effects.
  Pins ctypes return types to avoid DWORD-vs-signed-int parse bugs
  on WAIT_TIMEOUT (0x102). Distinguishes ERROR_INVALID_PARAMETER
  (PID gone) from ERROR_ACCESS_DENIED (alive but another user).
- On POSIX: the canonical ``os.kill(pid, 0)`` idiom that actually is
  a no-op there.

Then patch every ``os.kill(pid, 0)`` liveness-check callsite to
route through ``_pid_exists`` instead. Total 14 callsites across
11 files; every single one was a latent silent-kill on Windows:

  gateway/run.py:2810      — /restart watcher (inline subprocess)
  gateway/run.py:15195     — --replace wait loop
  gateway/status.py:572    — acquire_gateway_runtime_lock stale check
  gateway/status.py:828    — get_running_pid (THE killer for status)
  gateway/platforms/whatsapp.py:111
  hermes_cli/gateway.py:228, 522, 1012  — gateway-related drain loops
  hermes_cli/kanban_db.py:2826         — _pid_alive was claiming to
                                         be cross-platform but used
                                         os.kill(pid, 0) on Windows
  hermes_cli/main.py:5792        — CLI process-kill polling
  hermes_cli/profiles.py:782     — profile stop wait loop
  plugins/google_meet/process_manager.py:74
  tools/browser_tool.py:1215, 1255  — browser daemon ownership probes
  tools/mcp_tool.py:1255, 3374     — MCP stdio orphan tracking

The watcher source in gateway/run.py:2810 is a multi-line string
that gets spawned as an inline ``python -c "..."`` subprocess, so
it can't import gateway.status. The fix for that callsite inlines
the same ctypes probe directly into the watcher source.

Tested on Windows 10 with the hermes gateway + Telegram bot:
- gateway start → alive
- 5 consecutive ``hermes gateway status`` invocations → gateway
  alive after every one, same PID reported each time (37520, 21952)
- gateway.log shows uninterrupted operation; no spurious shutdown
  entries; cron ticker and kanban dispatcher still running on
  their 60-second cadence
- bot continues answering Telegram messages throughout

Ships alongside an exit-path diagnostic wrapper in
``hermes_cli/gateway.py::run_gateway()`` that captures every way
``asyncio.run(start_gateway(...))`` can return (success, SystemExit,
KeyboardInterrupt, BaseException, atexit) with full traceback to
``logs/gateway-exit-diag.log``. This was used to prove the gateway
was being hard-killed externally (no exit event fired) and should
be kept for future Windows debugging.

Refs: https://bugs.python.org/issue14484
See also: references/windows-subprocess-sigint-storm.md in
the hermes-agent skill.
2026-05-08 14:27:40 -07:00
Teknium
0ba1e12abc fix(windows): browser tool + spurious SIGINT from subprocess spawning
Three related Windows-only fixes that together make the browser toolset
actually usable on Windows. Symptom chain: user invokes browser_navigate
-> tool returns {"success": false, "error": "Daemon process exited
during startup with no error output"} and the CLI exits mid-turn with
the session summary.

Root cause (3 layers):

1. tools/browser_tool.py::_find_agent_browser() resolved
   node_modules/.bin/agent-browser to the extensionless POSIX shell
   shim via Path.exists(). On Windows, CreateProcessW cannot execute
   that script (WinError 193 "not a valid Win32 application"). Fix:
   delegate to shutil.which with path=node_modules/.bin so PATHEXT
   picks up agent-browser.CMD on Windows and the extensionless shim
   stays correct on POSIX.

2. Windows Terminal / Win32 delivers a spurious CTRL_C_EVENT to the
   parent hermes.exe whenever a background thread spawns a .cmd
   subprocess. Python 3.11's default SIGINT handler raises
   KeyboardInterrupt in MainThread, which unwinds prompt_toolkit's
   app.run() -> cli.py::run()'s finally block calls _run_cleanup()
   -> _emergency_cleanup_all_sessions -> spawns a concurrent
   _run_browser_command("close", ...) on the same session the agent
   thread just opened. Two agent-browser processes race on the same
   --session name, the daemon startup loses, and the tool returns
   the "Daemon process exited during startup" error. Fix: install a
   Windows-only SIGINT handler that absorbs the signal silently.
   Real user Ctrl+C still routes through prompt_toolkit's own c-c
   keybinding at the TUI layer, which is how Claude Code handles the
   same quirk (driving cancellation via the TUI key handler, not
   signals).

3. In tools/browser_tool.py, both Popen sites now pass
   creationflags=CREATE_NO_WINDOW | STARTF_USESTDHANDLES with
   close_fds=True on Windows. CREATE_NO_WINDOW suppresses the .cmd
   console flash; STARTF_USESTDHANDLES + close_fds ensures the child
   inherits only our three chosen handles (DEVNULL stdin, temp-file
   stdout/stderr) and no leaked parent console handles that could
   confuse agent-browser's native daemon spawn. Notably we do NOT
   add CREATE_NEW_PROCESS_GROUP - on Python 3.11 Windows the flag
   interacts badly with asyncio's ProactorEventLoop and makes things
   worse.

Verified end-to-end on Windows 10 / Windows Terminal / PowerShell:
browser_navigate to https://example.com returns
{"success": true, "title": "Example Domain"} and the CLI stays alive
for follow-up tool calls and assistant turns.

Refs: earlier Windows quirks commits 1cebb3bad (Ctrl+Enter newline),
26f5af52a (environment hints), aefd1a37f (Playwright Chromium).
2026-05-08 14:27:40 -07:00
Teknium
cbce5e93fc codebase: add encoding='utf-8' to all bare open() calls (PLW1514)
Closes the last Python-on-Windows UTF-8 exposure by making every
text-mode open() call explicit about its encoding.

Before: on Windows, bare open(path, 'r') defaults to the system
locale encoding (cp1252 on US-locale installs).  That means reading
any config/yaml/markdown/json file with non-ASCII content either
crashes with UnicodeDecodeError or silently mis-decodes bytes.

After: all 89 affected call sites in production code now pass
encoding='utf-8' explicitly.  Works identically on every platform
and every locale, no surprise behavior.

Mechanical sweep via:
  ruff check --preview --extend-select PLW1514 --unsafe-fixes --fix     --exclude 'tests,venv,.venv,node_modules,website,optional-skills,               skills,tinker-atropos,plugins' .

All 89 fixes have the same shape: open(x) or open(x, mode) became
open(x, encoding='utf-8') or open(x, mode, encoding='utf-8').  Nothing
else changed.  Every modified file still parses and the Windows/sandbox
test suite is still green (85 passed, 14 skipped, 0 failed across
tests/tools/test_code_execution_windows_env.py +
tests/tools/test_code_execution_modes.py + tests/tools/test_env_passthrough.py +
tests/test_hermes_bootstrap.py).

Scope notes:
  - tests/ excluded: test fixtures can use locale encoding intentionally
    (exercising edge cases).  If we want to tighten tests later that's
    a separate PR.
  - plugins/ excluded: plugin-specific conventions may differ; plugin
    authors own their code.
  - optional-skills/ and skills/ excluded: skill scripts are user-authored
    and we don't want to mass-edit them.
  - website/ and tinker-atropos/ excluded: vendored / generated content.

46 files touched, 89 +/- lines (symmetric replacement).  No behavior
change on POSIX or on Windows when the file is ASCII; bug fix on
Windows when the file contains non-ASCII.
2026-05-08 14:27:40 -07:00
Teknium
e93bfc6c93 feat(windows): close remaining POSIX-only landmines — TUI crash, kanban waitpid, AF_UNIX sandbox, /bin/bash, npm .cmd shims, cwd tracking, detach flags
Second pass on native Windows support, driven by a systematic audit across
five areas: POSIX-only primitives (signal.SIGKILL/SIGHUP/SIGPIPE, os.WNOHANG,
os.setsid), path translation bugs (/c/Users → C:\Users), subprocess patterns
(npm.cmd batch shims, start_new_session no-op on Windows), subsystem health
(cron, gateway daemon, update flow), and module-level import guards.

Every change is platform-gated — POSIX (Linux/macOS) behaviour is preserved
bit-identical. Explicit "do no harm" test: test_posix_path_preserved_on_linux,
test_posix_noop, test_windows_detach_popen_kwargs_is_posix_equivalent_on_posix.

## New module

- hermes_cli/_subprocess_compat.py — shared helpers (resolve_node_command,
  windows_detach_flags, windows_hide_flags, windows_detach_popen_kwargs).
  All no-ops on non-Windows.

## CRITICAL fixes (would crash or silently break on Windows)

- tui_gateway/entry.py: SIGPIPE/SIGHUP referenced at module top level would
  AttributeError on import on Windows, breaking `hermes --tui` entirely (it
  spawns this module as a subprocess).  Guard each signal.signal() call with
  hasattr() and add SIGBREAK as Windows' SIGHUP equivalent.

- hermes_cli/kanban_db.py: os.waitpid(-1, os.WNOHANG) in dispatcher tick was
  unguarded.  os.WNOHANG doesn't exist on Windows.  Gate the whole reap loop
  behind `os.name != "nt"` — Windows has no zombies anyway.

- tools/code_execution_tool.py: AF_UNIX socket for execute_code RPC fails on
  most Windows builds.  Fall back to loopback TCP (AF_INET on 127.0.0.1:0
  ephemeral port) when _IS_WINDOWS.  HERMES_RPC_SOCKET env var now accepts
  either a filesystem path (POSIX) or `tcp://127.0.0.1:<port>` (Windows).
  Generated sandbox client parses both.

- cron/scheduler.py: `argv = ["/bin/bash", str(path)]` hardcoded.  Use
  shutil.which("bash") so Windows (Git Bash via MinGit) works, with a
  readable error when bash is genuinely absent.

- 6 bare npm/npx spawn sites: tools_config.py x2, doctor.py, whatsapp.py
  (npm install + node version probe), browser_tool.py x2.  On Windows npm
  is npm.cmd / npx is npx.cmd (batch shims); subprocess.Popen(["npm", ...])
  fails with WinError 193.  shutil.which(...) returns the absolute .cmd
  path which CreateProcessW accepts because the extension routes through
  cmd.exe /c.  POSIX behaviour unchanged (shutil.which still returns the
  same path subprocess would resolve itself).

## HIGH fixes (silent misbehaviour on Windows)

- tools/environments/local.py get_temp_dir: hardcoded /tmp returned on
  Windows meant `_cwd_file = "/tmp/hermes-cwd-*.txt"`, which bash wrote
  via MSYS2's virtual /tmp but native Python couldn't open.  Result: cwd
  tracking silently broken — `cd` in terminal tool did nothing.  Windows
  branch now returns `%HERMES_HOME%/cache/terminal` with forward slashes
  (works in both bash and Python, guaranteed no spaces).

- tools/environments/local.py _make_run_env PATH injection: `/usr/bin not
  in split(":")` heuristic mangles Windows PATH (";" separator).  Gate
  the injection behind `not _IS_WINDOWS`.

- hermes_cli/gateway.py launch_detached_profile_gateway_restart: outer
  Popen + watcher-script Popen both used start_new_session=True, which
  Windows silently ignores.  Watcher stayed attached to CLI's console,
  died when user closed terminal after `hermes update`, left gateway
  stale.  Now branches through windows_detach_popen_kwargs() helper
  (CREATE_NEW_PROCESS_GROUP | DETACHED_PROCESS | CREATE_NO_WINDOW on
  Windows, start_new_session=True on POSIX — identical to main).

## MEDIUM fixes

- gateway/run.py /restart and /update handlers: hardcoded bash/setsid
  chain crashes on Windows when user triggers /update in-gateway.  Now
  has sys.platform=="win32" branch using sys.executable + a tiny
  Python watcher with proper detach flags.  POSIX path is unchanged.

- cli.py _git_repo_root: Git on Windows sometimes returns /c/Users/...
  style paths that break subprocess.Popen(cwd=...) and Path().resolve().
  Added _normalize_git_bash_path() helper that translates /c/Users,
  /cygdrive/c, /mnt/c variants to native C:\Users form.  POSIX no-op.
  _git_repo_root() now routes every result through it.

- cli.py worktree .worktreeinclude: os.symlink on directories failed
  hard on Windows (requires admin or Developer Mode).  Falls back to
  shutil.copytree with a warning log.

## Tests

- 29 new tests in tests/tools/test_windows_native_support.py covering:
  subprocess_compat helpers, TUI entry signal guards, kanban waitpid
  guard, code_execution TCP fallback source-level invariants, cron bash
  resolution, npm/npx bare-spawn lint per-file, local env Windows temp
  dir, PATH injection gating, git bash path normalization, symlink
  fallback, gateway detached watcher flags.

- One existing test assertion adjusted in test_browser_homebrew_paths:
  it compared captured Popen argv to the BARE `"npx"` literal; after the
  shutil.which() change argv[0] is the absolute path.  New assertion
  checks the shape (two items, second is `agent-browser`) rather than
  the exact first-item string.  Behaviour unchanged; test was too strict.

All 56 tests pass on Linux (30 from previous commits + 26 new).
267 tests from the affected files/dirs (browser, code_exec, local_env,
process_registry, kanban_db, windows_compat) all pass — zero regressions.
tests/hermes_cli/ (3909 pass) and tests/gateway/ (5021 pass) unchanged;
all pre-existing test failures confirmed unrelated via `git stash` re-run.

## What's still deferred (LOW priority)

- Visible cmd-window flashes on short-lived console apps (~14 sites) —
  cosmetic, needs a follow-up pass once we have user reports.
- agent/file_safety.py POSIX-only security deny patterns — separate
  hardening task.
- tools/process_registry.py returning "/tmp" as fallback — theoretical;
  reachable only when all env-var candidates fail.
2026-05-08 14:27:40 -07:00
Teknium
9de893e3b0 feat(windows): close native-Windows install gaps — crash-free startup, UTF-8 stdio, tzdata dep, docs
Native Windows (with Git for Windows installed) can now run the Hermes CLI
and gateway end-to-end without crashing.  install.ps1 already existed and
the Git Bash terminal backend was already wired up — this PR fills the
remaining gaps discovered by auditing every Windows-unsafe primitive
(`signal.SIGKILL`, `os.kill(pid, 0)` probes, bare `fcntl`/`termios`
imports) and by comparing hermes against how Claude Code, OpenCode, Codex,
and Cline handle native Windows.

## What changed

### UTF-8 stdio (new module)
- `hermes_cli/stdio.py` — single `configure_windows_stdio()` entry point.
  Flips the console code page to CP_UTF8 (65001), reconfigures
  `sys.stdout`/`stderr`/`stdin` to UTF-8, sets `PYTHONIOENCODING` + `PYTHONUTF8`
  for subprocesses.  No-op on non-Windows.  Opt out via `HERMES_DISABLE_WINDOWS_UTF8=1`.
- Called early in `cli.py::main`, `hermes_cli/main.py::main`, and
  `gateway/run.py::main` so Unicode banners (box-drawing, geometric
  symbols, non-Latin chat text) don't `UnicodeEncodeError` on cp1252
  consoles.

### Crash sites fixed
- `hermes_cli/main.py:7970` (hermes update → stuck gateway sweep): raw
  `os.kill(pid, _signal.SIGKILL)` → `gateway.status.terminate_pid(pid, force=True)`
  which routes through `taskkill /T /F` on Windows.
- `hermes_cli/profiles.py::_stop_gateway_process`: same fix — also
  converted SIGTERM path to `terminate_pid()` and widened OSError catch
  on the intermediate `os.kill(pid, 0)` probe.
- `hermes_cli/kanban_db.py:2914, 3041`: raw `signal.SIGKILL` →
  `getattr(signal, "SIGKILL", signal.SIGTERM)` fallback (matches the
  pattern already used in `gateway/status.py`).

### OSError widening on `os.kill(pid, 0)` probes
Windows raises `OSError` (WinError 87) for a gone PID instead of
`ProcessLookupError`.  Widened the catch at:
- `gateway/run.py:15101` (`--replace` wait-for-exit loop — without this,
  the loop busy-spins the full 10s every Windows gateway start)
- `hermes_cli/gateway.py:228, 460, 940`
- `hermes_cli/profiles.py:777`
- `tools/process_registry.py::_is_host_pid_alive`
- `tools/browser_tool.py:1170, 1206`

### Dashboard PTY graceful degradation
`hermes_cli/pty_bridge.py` depends on `fcntl`/`termios`/`ptyprocess`,
none of which exist on native Windows.  Previously a Windows dashboard
would crash on `import hermes_cli.web_server` because of a top-level
import.  Now:
- `hermes_cli/web_server.py` wraps the pty_bridge import in
  `try/except ImportError` and sets `_PTY_BRIDGE_AVAILABLE=False`.
- The `/api/pty` WebSocket handler returns a friendly "use WSL2 for
  this tab" message instead of exploding.
- Every other dashboard feature (sessions, jobs, metrics, config
  editor) runs natively on Windows.

### Dependency
- `pyproject.toml`: add `tzdata>=2023.3; sys_platform == 'win32'` so
  Python's `zoneinfo` works on Windows (which has no IANA tzdata
  shipped with the OS).  Credits @sprmn24 (PR #13182).

### Docs
- README.md: removed "Native Windows is not supported"; added
  PowerShell one-liner and Git-for-Windows prerequisite note.
- `website/docs/getting-started/installation.md`: new Windows section
  with capability matrix (everything native except the dashboard
  `/chat` PTY tab, which is WSL2-only).
- `website/docs/user-guide/windows-wsl-quickstart.md`: reframed as
  "WSL2 as an alternative to native" rather than "the only way".
- `website/docs/developer-guide/contributing.md`: updated
  cross-platform guidance with the `signal.SIGKILL` / `OSError`
  rules we enforce now.
- `website/docs/user-guide/features/web-dashboard.md`: acknowledged
  native Windows works for everything except the embedded PTY pane.

## Why this shape

Pulled from a survey of how other agent codebases handle native
Windows (Claude Code, OpenCode, Codex, Cline):

- All four treat Git Bash as the canonical shell on Windows, same as
  hermes already does in `tools/environments/local.py::_find_bash()`.
- None of them force `SetConsoleOutputCP` — but they don't have to,
  Node/Rust write UTF-16 to the Win32 console API.  Python does not get
  that for free, so we flip CP_UTF8 via ctypes.
- None of them ship PowerShell-as-primary-shell (Claude Code exposes
  PS as a secondary tool; scope creep for this PR).
- All of them use `taskkill /T /F` for force-kill on Windows, which
  is exactly what `gateway.status.terminate_pid(force=True)` does.

## Non-goals (deliberate scope limits)

- No PowerShell-as-a-second-shell tool — worth designing separately.
- No terminal routing rewrite (#12317, #15461, #19800 cluster) — that's
  the hardest design call and needs a separate doc.
- No wholesale `open()` → `open(..., encoding="utf-8")` sweep (Tianworld
  cluster) — will do as follow-up if users hit actual breakage; most
  modern code already specifies it.

## Validation

- 28 new tests in `tests/tools/test_windows_native_support.py` — all
  platform-mocked, pass on Linux CI.  Cover:
  - `configure_windows_stdio` idempotency, opt-out, env-preservation
  - `terminate_pid` taskkill routing, failure → OSError, FileNotFoundError fallback
  - `getattr(signal, "SIGKILL", …)` fallback shape
  - `_is_host_pid_alive` OSError widening (Windows-gone-PID behavior)
  - Source-level checks that all entry points call `configure_windows_stdio`
  - pty_bridge import-guard present in `web_server.py`
  - README no longer says "not supported"
- 12 pre-existing tests in `tests/tools/test_windows_compat.py` still pass.
- `tests/hermes_cli/` ran fully (3909 passed, 9 failures — all confirmed
  pre-existing on main by stash-test).
- `tests/gateway/` ran fully (5021 passed, 1 pre-existing failure).
- `tests/tools/test_process_registry.py` + `test_browser_*` pass.
- Manual smoke: `import hermes_cli.stdio; import gateway.run;
  import hermes_cli.web_server` — all clean, `_PTY_BRIDGE_AVAILABLE=True`
  on Linux (as expected).

## Files

- New: `hermes_cli/stdio.py`, `tests/tools/test_windows_native_support.py`
- Modified: `cli.py`, `gateway/run.py`, `hermes_cli/main.py`,
  `hermes_cli/profiles.py`, `hermes_cli/gateway.py`,
  `hermes_cli/kanban_db.py`, `hermes_cli/pty_bridge.py`,
  `hermes_cli/web_server.py`, `tools/browser_tool.py`,
  `tools/process_registry.py`, `pyproject.toml`, `README.md`, and 4
  docs pages.

Credits to everyone whose prior PR work informed these fixes — see
the co-author trailers.  All of the PRs listed in
`~/.hermes/plans/windows-support-prs.md` fixing `os.kill` / `signal.SIGKILL`
/ UTF-8 stdio / tzdata / README patterns found the same issues; this PR
consolidates them.

Co-authored-by: Philip D'Souza <9472774+PhilipAD@users.noreply.github.com>
Co-authored-by: Arecanon <42595053+ArecaNon@users.noreply.github.com>
Co-authored-by: XiaoXiao0221 <263113677+XiaoXiao0221@users.noreply.github.com>
Co-authored-by: Lars Hagen <1360677+lars-hagen@users.noreply.github.com>
Co-authored-by: Luan Dias <65574834+luandiasrj@users.noreply.github.com>
Co-authored-by: Ruzzgar <ruzzgarcn@gmail.com>
Co-authored-by: sprmn24 <oncuevtv@gmail.com>
Co-authored-by: adybag14-cyber <252811164+adybag14-cyber@users.noreply.github.com>
Co-authored-by: Prasanna28Devadiga <54196612+Prasanna28Devadiga@users.noreply.github.com>
2026-05-08 14:27:40 -07:00
Teknium
0214858ef5
fix(browser): enforce cloud-metadata SSRF floor in hybrid routing (#16234) (#21228)
Cloud metadata endpoints (169.254.169.254 etc.) are now always blocked
by browser_navigate regardless of hybrid routing, allow_private_urls,
or backend.

Bug: commit 42c076d3 (#16136) added hybrid routing that flips
auto_local_this_nav=True for private URLs and short-circuits
_is_safe_url(). IMDS endpoints are technically private (169.254/16
link-local), so the sidecar happily routed them to a local Chromium,
and the agent could read IAM credentials via browser_snapshot. On
EC2/GCP/Azure this is a full SSRF-to-credential-theft.

Fix: new is_always_blocked_url() in url_safety.py — a narrow floor
that checks _BLOCKED_HOSTNAMES, _ALWAYS_BLOCKED_IPS,
_ALWAYS_BLOCKED_NETWORKS only. Applied as an independent gate in
browser_navigate's pre-nav and post-redirect checks, BEFORE
auto_local_this_nav gets a chance to short-circuit. Ordinary private
URLs (localhost, 192.168.x, 10.x, .local, CGNAT) still route to the
local sidecar as the #16136 feature intends.

Secondary fix (reporter's finding): _url_is_private() now explicitly
checks 172.16.0.0/12. ipaddress.is_private only covers that range on
Python ≥3.11 (bpo-40791), so on 3.10 runtimes those URLs were routed
to cloud instead of the local sidecar. No security impact — just a
correctness fix for the hybrid-routing feature.

Closes #16234.
2026-05-07 05:38:05 -07:00
Kshitij Kapoor
629d8b843d fix(browser): tighten Lightpanda fallback edge cases 2026-05-06 03:41:21 -07:00
Kshitij Kapoor
3ebdd26449 fix(browser): surface Lightpanda Chrome fallback warnings 2026-05-06 03:23:19 -07:00