Follow-up for salvaged PR #14179.
`_cleanup_invalid_pid_path` previously called `remove_pid_file()` for the
default PID path, but that helper defensively refuses to delete a PID file
whose pid field differs from `os.getpid()` (to protect --replace handoffs).
Every realistic stale-PID scenario is exactly that case: a crashed/Ctrl+C'd
gateway left behind a PID file owned by a now-dead foreign PID.
Once `get_running_pid()` has confirmed the runtime lock is inactive, the
on-disk metadata is known to belong to a dead process, so we can force-unlink
both the PID file and the sibling `gateway.lock` directly instead of going
through the defensive helper.
Also adds a regression test with a dead foreign PID that would have failed
against the previous cleanup logic.
Follow-up on top of opriz's atomic PID file fix. The prior change caught
the race AFTER runner.start(), so the loser still opened Telegram polling
and Discord gateway sockets before detecting the conflict and exiting.
Hoist the PID-claim block to BEFORE runner.start(). Now the loser of the
O_CREAT|O_EXCL race returns from start_gateway() without ever bringing up
any platform adapter — no Telegram conflict, no Discord duplicate session.
Also add regression tests:
- test_write_pid_file_is_atomic_against_concurrent_writers: second
write_pid_file() raises FileExistsError rather than clobbering.
- Two existing replace-path tests updated to stateful mocks since the
real post-kill state (get_running_pid None after remove_pid_file)
is now exercised by the hoisted re-check.
* fix(gateway): detect legacy hermes.service units from pre-rename installs
Older Hermes installs used a different service name (hermes.service) before
the rename to hermes-gateway.service. When both units remain installed, they
fight over the same bot token — after PR #5646's signal-recovery change,
this manifests as a 30-second SIGTERM flap loop between the two services.
Detection is an explicit allowlist (no globbing) plus an ExecStart content
check, so profile units (hermes-gateway-<profile>.service) and unrelated
third-party services named 'hermes' are never matched.
Wired into systemd_install, systemd_status, gateway_setup wizard, and the
main hermes setup flow — anywhere we already warn about scope conflicts now
also warns about legacy units.
* feat(gateway): add migrate-legacy command + install-time removal prompt
- New hermes_cli.gateway.remove_legacy_hermes_units() removes legacy
unit files with stop → disable → unlink → daemon-reload. Handles user
and system scopes separately; system scope returns path list when not
running as root so the caller can tell the user to re-run with sudo.
- New 'hermes gateway migrate-legacy' subcommand (with --dry-run and -y)
routes to remove_legacy_hermes_units via gateway_command dispatch.
- systemd_install now offers to remove legacy units BEFORE installing
the new hermes-gateway.service, preventing the SIGTERM flap loop that
hits users who still have pre-rename hermes.service around.
Profile units (hermes-gateway-<profile>.service) remain untouched in
all paths — the legacy allowlist is explicit (_LEGACY_SERVICE_NAMES)
and the ExecStart content check further narrows matches.
* fix(gateway): mark --replace SIGTERM as planned so target exits 0
PR #5646 made SIGTERM exit the gateway with code 1 so systemd's
Restart=on-failure revives it after unexpected kills. But when a user has
two gateway units fighting for the same bot token (e.g. legacy
hermes.service + hermes-gateway.service from a pre-rename install), the
--replace takeover itself becomes the 'unexpected' SIGTERM — the loser
exits 1, systemd revives it 30s later, and the cycle flaps indefinitely.
Before calling terminate_pid(), --replace now writes a short-lived marker
file naming the target PID + start_time. The target's shutdown_signal_handler
consumes the marker and, when it names this process, leaves
_signal_initiated_shutdown=False so the final exit code stays 0.
Staleness defences:
- PID + start_time combo prevents PID reuse matching an old marker
- Marker older than 60s is treated as stale and discarded
- Marker is unlinked on first read even if it doesn't match this process
- Replacer clears the marker post-loop + on permission-denied give-up
Updated the acquire_scoped_lock function to treat empty or corrupt lock files as stale. This change ensures that if a lock file exists but is invalid, it will be removed to prevent issues with stale locks. Added tests to verify recovery from both empty and corrupt lock files.
Recognize hermes_cli/main.py gateway command lines in gateway
process detection and PID validation so --replace reliably finds
existing gateway instances.
Adds a regression test covering script-style cmdline detection.
Closes#1830
Verifies that write_runtime_status() overwrites pid and start_time
from a previous process rather than preserving them via setdefault().
Covers the fix from PR #1632.
Salvaged from PR #1470 by adavyas.
Core fix: Honcho tool calls in a multi-session gateway could route to
the wrong session because honcho_tools.py relied on process-global
state. Now threads session context through the call chain:
AIAgent._invoke_tool() → handle_function_call() → registry.dispatch()
→ handler **kw → _resolve_session_context()
Changes:
- Add _resolve_session_context() to prefer per-call context over globals
- Plumb honcho_manager + honcho_session_key through handle_function_call
- Add sync_honcho=False to run_conversation() for synthetic flush turns
- Pass honcho_session_key through gateway memory flush lifecycle
- Harden gateway PID detection when /proc cmdline is unreadable
- Make interrupt test scripts import-safe for pytest-xdist
- Wrap BibTeX examples in Jekyll raw blocks for docs build
- Fix thread-order-dependent assertion in client lifecycle test
- Expand Honcho docs: session isolation, lifecycle, routing internals
Dropped from original PR:
- Indentation change in _create_request_openai_client that would move
client creation inside the lock (causes unnecessary contention)
Co-authored-by: adavyas <adavyas@users.noreply.github.com>
- store gateway PID metadata and validate the live process before trusting gateway.pid
- auto-refresh outdated systemd user units before start/restart so installs pick up --replace fixes
- sweep stray manual gateway processes after service stops
- add regression tests for PID validation and service drift recovery