opentui(phase3): launcher integration — HERMES_TUI_ENGINE dual-engine

hermes --tui launches the native OpenTUI engine (Bun) when
HERMES_TUI_ENGINE=opentui (env) or display.tui_engine=opentui (config);
Ink stays the default and the shipping path is untouched.

- _resolve_tui_engine() (env > config > ink); refuses opentui on
  Windows/Termux (no Bun) -> falls back to ink with a notice.
- _make_opentui_argv() -> [bun, src/entry.real.tsx] (no build step).
- _bun_bin() with HERMES_BUN override.
- Branch at top of _make_tui_argv BEFORE _ensure_tui_node (Bun-only host
  must not bootstrap Node).
- Gate _launch_tui NODE_OPTIONS/--max-old-space-size on engine==ink (Bun
  is JSC; the V8 flag errors/ignores).

Verified end-to-end via tmux: real hermes --tui -> Bun -> OpenTUI ->
real Python gateway streamed a real reply. No-flag default still ink.
This commit is contained in:
alt-glitch 2026-06-08 11:11:54 +00:00
parent 24f74eb888
commit 2bd9c9b881
741 changed files with 17733 additions and 79889 deletions

View file

@ -250,79 +250,3 @@ def test_stale_gateway_pid_cleaned_up_on_restart(restart_container: str) -> None
assert r.returncode != 0, "stale gateway.pid survived restart"
r = _sh(container, "test -f /opt/data/profiles/ghost/processes.json")
assert r.returncode != 0, "stale processes.json survived restart"
def test_live_gateway_autostarts_after_real_restart_without_manual_state_stamp(
restart_container: str,
) -> None:
"""End-to-end guard for issue #42675.
The other tests in this module stamp gateway_state.json directly to
exercise the reconciler's READ side. This one exercises the WRITE
side: a real, live gateway is killed by the container/s6 SIGTERM that
`docker restart` sends no manual state stamp and must come back up
on the next boot.
Before the fix, the shutdown handler unconditionally persisted
gateway_state=stopped on that SIGTERM, so the reconciler saw 'stopped'
and registered the slot DOWN the gateway silently stayed dark after
every container restart. The fix classifies an unmarked SIGTERM as
signal-initiated and persists 'running' instead, so auto-start works.
"""
container = restart_container
_exec(container, "hermes", "profile", "create", "live").check_returncode()
r = _exec(container, "hermes", "-p", "live", "gateway", "start", timeout=60)
assert r.returncode == 0, f"gateway start failed: {r.stderr}"
# Wait for the gateway to actually come up under supervision AND write
# its own gateway_state=running (we do NOT stamp it ourselves).
deadline = time.monotonic() + 20.0
while time.monotonic() < deadline:
r = _sh(container, "/command/s6-svstat /run/service/gateway-live")
if r.returncode == 0 and "up " in r.stdout:
break
time.sleep(0.5)
assert "up " in r.stdout, f"gateway never came up pre-restart: {r.stdout!r}"
# Confirm the gateway persisted its own 'running' state (sanity: we're
# testing the real write path, not a stamped fixture).
deadline = time.monotonic() + 15.0
state = ""
while time.monotonic() < deadline:
r = _sh(
container,
"cat /opt/data/profiles/live/gateway_state.json 2>/dev/null",
)
if r.returncode == 0 and '"gateway_state"' in r.stdout:
state = r.stdout
break
time.sleep(0.5)
assert '"running"' in state, (
f"gateway never persisted running state pre-restart: {state!r}"
)
# Real restart — Docker sends SIGTERM to PID 1; s6 propagates it to the
# supervised gateway. No planned-stop marker is written (this is not an
# operator `hermes gateway stop`), so the shutdown is signal-initiated.
_docker("restart", container, timeout=60).check_returncode()
log = _wait_for_reconcile_log_mention(container, "live", deadline_s=30.0)
assert "profile=live" in log, (
f"reconciler never logged live after restart: {log!r}"
)
# The crux: the reconciler must AUTO-START it, not register it down.
assert "action=started" in log, (
f"gateway did NOT auto-start after a real restart (issue #42675 "
f"regression): {log!r}"
)
# Slot recreated, and NO down marker (we expect auto-start).
assert _wait_for_path(
container, "/run/service/gateway-live", kind="d", deadline_s=10.0,
), "slot not recreated after restart"
r = _sh(container, "test -f /run/service/gateway-live/down")
assert r.returncode != 0, (
"down marker present despite a live gateway being restarted — "
"the signal-initiated shutdown wrongly persisted 'stopped' (#42675)"
)